background image

8

Type

PEV-1/4A-SW27

PEV-1/4A- WD

Part No.

159 259

161209

Design

Mechanical pressure switch

Angle socket

Medium

Filtered unlubricated compressedair (degree of filtration min. 40 

µ

m)

Installation position

Any

Permissible pressure range
Adjustable switching pressure

0...10 bar
1...10 bar

Permissible temperature

- Storage temperature

ranges:

- Ambient temperature
- Medium temperature

-20° C ... +60° C
-20° C ... +100° C 
Dew point must not be reached at <1° C(use dried compressed air) 

Operating voltage

12 .. 250 V AC/DC

Switching current

50 mA ... max. 4A

Contact rating AC

max. 4A x 250 V AC

Contact rating DC:

Voltage [V DC]
Ohmic load [A]
Inductive loadt [A]
Incandescent load [A]

Up to   24
4
2
1.5

Up to   50
2
1
0.5

Up to   75
1
0.1
0.3

Up to 125
0.3
0.03
0.2

Up to 250
0.1
0.02
0.1

Switching time

On: 37 ms (typical)  Off: 29 ms typical

Degree of protection

IP 00 with direct connection via push-on connector
IP 65 with correctly-fitted connector socket

Hysteresis (relative to switch-on pressure)

(15 

±

 5)% bei 6 bar; (30 

±

 5)% bei 2 bar

Switching frequency

max. 3 Hz 

Materials: 1. Housing     2. Diaphragm

1. Galvanised steel    2.NBR  Cleaning: Soap solution, max. 60° C

Fig. 14

Technical specifications

0395

D/GB 11

Summary of Contents for PEV-1/4A Series

Page 1: ...socket Type PEV 1 4A WD Einbau und Inbetriebnahme nur von autorisiertem Fachpersonal gem Bedienungsanleitung Fitting and commissioning to be carried out by qualified personnel only in accordance with...

Page 2: ...be 4 Anschlu platte 5 Geh use 6 PG Verschraubung mit Dicht und Sicherungsring 7 Dichtring 8 Schl sselfl che 9 Compressed air connection 1 Electrical connection 2 Adjusting screw for switching point 3...

Page 3: ...Temperaturen Sorgen Sie f r ordnungsgem auf bereitete Druckluft Function and application The PEV interrupts or closes an electri cal circuit when a preset pressure value is reached changeover contact...

Page 4: ...Hinweise am Produkt in dieser Bedienungsanleitung Verwenden Sie das Produkt im Orig inalzustand ohne jegliche eigenm ch tige Ver nderung Please make allowance for the pre vailing environmental condit...

Page 5: ...dig Stellen Sie sicher da das Kabel fol genderma en verlegt ist quetschfrei knickfrei dehnungsfrei Fitting Mechanical pneumatic Screw the PEV into the desired com pressed air connection using a 27 mm...

Page 6: ...dose laut Zubeh r Anschlu verbindung Steck h lsen Verschraubung mit Anschlu platte 5 Schutzart IP 00 IP 65 bei sach gem er Vorgehensweise Bild 5 Wiring method a without angle socket b with angle socke...

Page 7: ...cksichtigen b Wiring with angle socket as described in Accessories 1 Remove the mounting screw 4 com pletely from the head end of the angle socket keep in safe place 2 Remove the detached connector p...

Page 8: ...are using an angle socket Pull off the angle socket For all connection methods 1 First screw the adjusting screw 3 fully inwards 2 Connect a continuity tester to contacts 1 and 4 3 Apply the desired s...

Page 9: ...im Entfernen der Winkeldose kein Typenschild am Druckschalter mehr verf gbar ist 4 Turn the adjusting screw counter clockwise until the PEV operates continuity tester reacts If you are using an angle...

Page 10: ...icht erreicht werden Luft trocknen Betriebsspannung 12 250 V AC DC zul ssiger Schaltstrom 50 mA max 4A Schaltleistung AC max 4A x 250 V AC Schaltleistung DC Spannung V DC Ohmsche Last A Induktive Last...

Page 11: ...e 12 250 V AC DC Switching current 50 mA max 4A Contact rating AC max 4A x 250 V AC Contact rating DC Voltage V DC Ohmic load A Inductive loadt A Incandescent load A Up to 24 4 2 1 5 Up to 50 2 1 0 5...

Page 12: ...ying or otherwise without the prior written permission of Festo KG We reserve the right to make altera tions St rung m gliche Ursache Abhilfe PEV schaltet nicht Schaltpunkt zu hoch Einstellschraube ei...

Reviews: