background image

Flow recording

The product continuously records the flow rate, prepares the data and makes it
available cyclically. To detect excessive flow rates, the product offers the option of
parameterising the upper limit value for the flow. If the parameterised limit value
is exceeded, the device will issue a diagnostic message via the bus node in exten-
sion series 1.

Consumption recording

The product determines the compressed air consumption by recording the system
flow rate. With the aid of output data, the consumption measurement can be
switched on and off and the consumption value can be reset.

Operational functions

The behaviour of the product can be changed by accessing the internal paramet-
ers, e. g.:

Diagnostic behaviour by enabling maskable diagnostic messages

Specification of the units and the measuring interval

Setting of limit values

The product is delivered with pre-set parameters. Fundamentals of parameterisa-
tion 

è

 8.3 Parameterisation. Detailed information on parameterisation

è

 1 Applicable documents.

6

Assembly

The product is intended for wall mounting. The mounting brackets are included in
the scope of delivery.

Fig. 2 Typical assembly

Prerequisite: the mounting surface is flat and can support the weight of the
product.
1. Adjust the product when it is standing vertically (± 5°).
2. Mount the product using the mounting brackets and 2 screws each. Screw

size: M6 If necessary, use washers.

Dimensions

1 Connecting thread M12, 8-pin

Fig. 3 Dimensions

7

Installation

Installation sequence:
1. Pneumatic connections
2. Earth terminal
3. Electrical connecting cable

7.1

Pneumatic installation

Requirements:

The product is assembled.

The contact surfaces must be clean (avoid leakage and contact errors).

Connect pneumatic connections 

1

, 

2

.

7.2

Electrical installation

NOTICE!

Material damage as a result of changing the connecting cable when the supply
voltage is switched on

Connect and remove the CPX-Extension connecting cable only when the sup-
ply voltage is switched off for the control extension series 1 device.

Only use pre-assembled connecting cables.

1. Connect the earth terminal.
2. Connect electrical connecting cables to the power supply

è

 5.1.3 Connecting components.

Electrical connection example

Electrical connection of the MSE6-D2M via the extension series 1 device
MSE6-C2M-…M.

1 Equipotential bonding between

the earth terminal of the left-hand
pneumatic sub-base and the left
end plate of the electrical interlink-
ing module

2 System supply

3 MSE6-D2M

4 Equipotential bonding of function-

al earth (FE)

5 Earth terminal pin 5

6 Power supply can be separately

disconnected for actuator techno-
logy and electrical inputs

7 External fuses

8 MSE6-C2M

Fig. 4 Power supply with separate circuits and equipotential bonding

7.3

Combination with MS6 modules

General information

Maximum permissible number of entire service unit component combina-
tion:10 individual modules. The product MSE6-D2M counts as a double mod-
ule here.

When supplementing MS6 modules, only use the wall mounting MS6-WPG
and the module connector MS6-MV-EX.

When supplementing MS6 modules, the screws on the module connector
between the flow sensor and the on/off valve may not be loosened

è

 Restriction of EMC immunity to interference.

Observe the assembly instructions for the wall mounting-SET MS6-WPG.

In the case of a larger device configuration, a longer FE connection is
required.

The cable has a nominal cross section of 5 mm

2

 with cable lug in accord-

ance with DIN 46234-4-6.

Alternatively: earthing straps are manufactured in a bare or tin-plated
design in accordance with DIN 46444 or in accordance with DIN 72333-3.
Nominal cross section: 

>

 5 mm

2

. Connection: M4.

Assembly

1. For pre-assembled MS6 combinations: replace the wall brackets with a

MS6-WPG wall mounting-SET.

2. For MS6 individual modules: replace module connectors for pre-assembled

MS6 combinations with MS6-MV-EX module connectors.

3. For additions to the left side: remove the left-hand pneumatic sub-base of the

MS6 module or MS6 module combination. At this point, assemble the left
pneumatic sub-base of the product.

4. For additions to the right side: remove the right-hand pneumatic sub-base of

the MS6 module or MS6 module combination. At this point, assemble the
right pneumatic sub-base of the product.

Reviews: