Festo — MSE6-C2M — 2022-08b
Installation
45
2. Mount the product using the mounting brackets and 2 screws each. Screw size: M6. If necessary,
use washers.
Dimensions
Fig. 18: Dimensions, example MSE6-C2M-5000-FB44-DM-RG-BAR-AMI-AGD
7
Installation
7.1
Pneumatic installation
Requirements:
–
The product is mounted.
–
The connection surfaces are clean.
è
leakage and contact errors are avoided.
1. Connect pneumatic connections 1 and 2.
2. Mount a silencer or the exhaust air duct at pneumatic port 3.
7.2
Electrical installation
WARNING
Risk of Injury due to Electric Shock.
• For the electric power supply, use only PELV circuits that ensure a reliable electric disconnection
from the mains network.
• Observe IEC 60204-1/EN 60204-1.
• The unit must be powered by a power source that fulfils the requirements of an energy-limited
circuit in accordance with IEC 61010-1/EN 61010-1.