Commissioning
To start up the device, proceed as follows:
1. Apply operating pressure p1.
2. Switch on the supply voltage.
The output pressure p2 is built up slowly. The filling time “t” is set through the
flow control screw attached to the cover. The output pressure rises correspond-
ing to the set throttle point (
Fig. 12). If the preset pressure switching point
(PSP) is reached, the main seat of the valve opens (
Fig. 13). The MS9-SV-...-C
is then ready for operation.
No further settings are required.
Tamper protection
To prevent a manipulation of the settings, setting and control elements can be
equipped with a cover
11 Accessories.
7
Operation
Note
Exhaust with a voltage drop
8
Maintenance and care
• Switch off the following sources of energy before cleaning the exterior of the
device:
– Operating voltage
– Compressed air
• If needed, clean the MS9-SV-...-C from outside.
Soap suds (max. +50 °C), petroleum ether and all non-abrasive cleaning agents
may be used.
9
Disassembly
Note
Residual pressure must be eliminated.
1. Switch off the following sources of energy before dismantling:
– Operating voltage
– Compressed air
2. Separate the respective connections from the MS9-SV-...-C.
10
De-commissioning and disposal
In coordination with the waste management company, the product can be com-
pletely disposed of through metal recycling (e.g. EAK 17 04 02). If necessary, the
solenoid valve is dismantled and disposed of separately in electronic scrap recyc-
ling (EAK 16 02 16).
11
Accessories
Designation
Type
Silencer
U-1-B
Cover
1)
MS9-SV-C-MH
Cover
2)
MS9-SV-C-MK
1)
covers the manual override
2)
covers pressure switching point, main throttle and manual override
Fig. 8
Accessories
Festo accessories can be found at:
www.festo.com/catalogue
12
Troubleshooting
Malfunction
Possible cause
Remedy
Valve switches abruptly
Pressure switching point too
low, flow control valve opened
too wide
Correct settings
Valve does not switch
Pressure switching point too
high, flow control valve not
opened widely enough
Correct settings
Fig. 9
Troubleshooting
13
Technical data
13.1 Safety-related characteristics
MS9-SV
-10V24P
-V24
-V110
-V230
Safety function
Venting
Performance Level (PL)
Venting: up to category 1, PL c
Max. pos. test pulse at logic 0
[µs]
3800
3200
–
–
Max. neg. test pulse at logic 1
[µs]
4900
2800
–
–
Venting time
[s]
13.5 Venting time
CE marking (see declaration of conformity)
–
To EU Low Voltage Dir-
ective
Fig. 10 Safety-related characteristics
13.2 General data
MS9-SV
-10V24P
-V24
-V110
-V230
Pneumatic connection 1
with accessories (connection sizes
Fig. 2)
Pneumatic connection 2
with accessories (connection sizes
Fig. 2)
Pneumatic connection 3
G1
NPT1
Type of mounting
In-line installation
With accessories
Mounting position
Any
Design
Piston slide
Actuation type
Electric
Exhaust function
No flow control
Type of control
Piloted
Valve function
3/2-way valve, monostably closed, pressure built-
up function adjustable
Operating medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Note on operating medium
Operation with lubricated medium possible (in
which case lubricated operation will always be re-
quired)
Operating pressure p1
[bar]
3.5 … 16
Pressure switching point
[bar]
adjustable
diagram Fig. 13
Venting flow rate
adjustable through flow control valve
diagram
Fig. 12
C-value 1
}
2
[l/(s*bar)]
-3/4:
57.61
-1
69.59
-AGD:
31.43
-AGE:
54.24
-AGF
68.24
-AGG
68.45
-AGH
66.07
C-value 2
}
3
[l/(s*bar)]
-3/4:
55.52
-1
54.01
-AGD:
56.22
-AGE:
54.07
-AGF
52.73
-AGG
51.06
-AGH
51.36
b-value 1
}
2
-3/4:
0.37
-1
0.32
-AGD:
0.47
-AGE:
0.37
-AGF
0.34
-AGG
0.35
-AGH
0.35
b-value 2
}
3
-3/4:
0.49
-1
0.46
-AGD:
0.60
-AGE:
0.49
-AGF
0.47
-AGG
0.45
-AGH
0.44
Standard nominal flow rate
1
}
2
[l/min]
-3/4/-N3/4: 14150
-1/-N1
16460
-AGD/-AQR: 8300
-AGE/-AQS:
13250
-AGF/-AQT:
16340
-AGG/-AQU: 16550
-AGH/-AQV: 15910
Standard flow rate 2
}
3
[l/min]
-3/4:
14790
-1
14140
-N3/4:
14900
-N1
14100
-AGD/-AQR: 16500
-AGE/-AQS:
14400
-AGF/-AQT:
13800
-AGG/-AQU: 13200
-AGH/-AQV: 13200
Ambient temperature
[°C]
0 … +60 (0 … +50 with pressure sensor)
Temperature of medium
[°C]
0 … +60 (0 … +50 with pressure sensor)
Storage temperature
[°C]
0 … +60 (0 … +50 with pressure sensor)
Shock resistance
Shock test with severity level 1 according to
FN 942017-5 and EN 60068-2-27
Vibration resistance
Transport application test with severity level 1 to
FN 942017-4 and EN 60068-2-6