4
Mounting
14
Festo – EXCM-40-EN – 2017-11a – English
4.3
Installation
Note
If there are temperature differences between the product and the mounting surface:
Adapt the temperature of the product to the temperature of the mounting surface.
Observe the permissible ambient temperatures
(
è
A.5 Operating and storage conditions).
1. Make sure that the product and mounting surface have the same temperature.
2. Make sure that all of the transport screws have been removed.
3. Attach appropriate lifting gear to the 4 transport lugs
2
and
6
(
è
1
2
3
4
1
5
6
4
5
6
2
1
End cap
2
Transport lug with support plate (2x)
3
Lifting gear
4
Transport restraint (2x)
5
Drive cover (motor side)
6
Transport lug (on transport restraint) (2x)
1)
not included in scope of delivery
Fig. 4.4
Depicted: EXCM-40-…-B (motor attachment position underneath).