![Festo EMCA-EC-67 CO Series Description Download Page 338](http://html.mh-extra.com/html/festo/emca-ec-67-co-series/emca-ec-67-co-series_description_2283329338.webp)
D CANopen
communication
338
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
D.7.2
Send EMCY message
When an error occurs, the EMCA transmits an EMCY message. In the default case, the CAN identifi
er (CAN-ID) of this message consists of the CAN identifier (80h) and the node number (Node-ID) of the
EMCA involved.
The EMCY message consists of 8 data bytes:
–
Data byte 1 and 2: contains the Error code
è
–
Data byte 3: contains the error type from the error register (Error register, object 1001h)
è
–
Data bytes 4 … 8: no further error register data available.
81
h
8
E0
E1
R0
...
...
...
...
...
CAN-ID: 80h + node ID (example node ID = 1)
Error code
Data length
Error register (Obj. 1001h)
Fig. D.8
Structure: EMCY message
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......