C
FHPP parameters (PNU)
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
303
C.3.21
Factor group
PNU 600
Position powers of ten exponent (Position notation index)
Subindex 1
Class: Var
Data type: int8
Access: rw2
Reading or parameterisation of the powers of 10 exponent with the 1 SINC converted to 1 basic unit
value.
Example:
Power of 10 exponent = -7
Basic unit (0x01) = metre
Calculation:
–
1 SINC: 1 * 10-7 m = 0.1 μm
–
10,000 SINC: 10,000 * 10-7 m = 1 mm
Tab. C.130 PNU 600
PNU 601
Position unit of measurement (Position dimension index)
Subindex 1
Class: Var
Data type: uint8
Access: rw2
Reading or parameterisation of the system of measurement in relation to the basic unit.
Value
Significance
0x00 (0)
Undefined/user-specific
0x01 (1)
Metre (SI unit)
0x41 (65)
Degree
0xF0 (240)
Inch
0xF6 (246)
Revolutions
Tab. C.131 PNU 601
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......