C
FHPP parameters (PNU)
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
271
PNU 238
Permitted fault handling 1 (Permissible malfunction handling 1)
Subindex 1 … 255
Class: Array
Data type: uint16
Mappable
Access: ro
Reading of the malfunction handlings for the malfunctions 0 ….254.
Bit
Value
Significance
0
0
Diagnostic message is warning.
1
Diagnostic message is malfunction (error).
1
0
Treat diagnostic message as malfunction or warning.
1
Ignore diagnostic message (information).
2
0
No entry in the diagnostic memory
1
Save in diagnostic memory
3 … 15
–
reserved
Subindex 1
Fault number 0 (Malfunction number 0)
Malfunction handling for the malfunction number 0.
Subindex 2
Fault number 1 (Malfunction number 1)
Malfunction handling for the malfunction number 1.
Subindex 3 … 255
Fault number 2 … 254 (Malfunction number 2 … 254)
Malfunction handling for the malfunction numbers 2 … 254.
Tab. C.39
PNU 238
PNU 242
Error response 1 (Error reaction 1)
Subindex 1 … 255
Class: Array
Data type: uint16
Mappable
Access: rw2
Reading or parameterisation of the error reactions for the malfunctions 0 ….254.
Definition of the permitted error responses (bitfield)
è
PNU 234.
Subindex 1
Fault number 0 (Malfunction number 0)
Error response for the malfunction number 0.
Subindex 2
Fault number 1 (Malfunction number 1)
Error response for the malfunction number 1.
Subindex 3 … 255
Fault number 2 … 254 (Malfunction number 2 … 254)
Error responses for the malfunction numbers 2 … 254.
Tab. C.40
PNU 242
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......