5.1.3
Mount accessories
To protect the end positions against uncontrolled overtravel:
Check the necessity of proximity sensors (hardware limit switches).
If proximity sensors are used as limit switches:
Preferably use proximity sensors with normally-closed function.
This protects against excess travel beyond the end position, if the proximity sensor cable is broken.
If proximity switches are used as reference switches:
Use proximity sensors that correspond to the input of the controller being used.
Use proximity sensors with switch lug (
è
Mounting instructions of the accessory).
Mounting options of the proximity sensor
in the slots
With sensor bracket
1
2
1
3
1
Switch lug
2
Slot for proximity sensor
3
Sensor bracket
Fig. 11
Avoid external influences from magnetic or ferritic parts in the vicinity of the proximity sensors (min
imum distance of 10 mm from the slot nuts).
Avoid contamination:
– Use slot covers in all unused slots
(
è
www.festo.com/catalogue).
– Connect sealing air. To do this, remove the threaded pin
(
9
è
Fig. 12) on the cover and connect compressed air/
vacuum.
Fig. 12