ELFC-KF
8
Festo – ELFC-KF – 2017-02 English
Size
32
45
60
80
Screw
M3
M4
M5
M6
Screw-in depth D
[mm]
4 … 5
6 … 7.5
8.5 … 10
11 … 14
Tightening torque
[Nm]
1.2
2.9
5.9
9.9
Centring H7
[mm]
@
2
@
4
@
5
@
7
Tab. 1
7.4
Mounting accessories
To protect the end positions against uncontrolled excess travel:
Check the necessity of proximity sensors (hardware limit switches).
If proximity sensors are used as limit switches:
Preferably use proximity sensors with normally closed function.
This protects against excess travel beyond the end position if the proximity sensor cable is broken.
If proximity switches are used as reference switches:
Use proximity sensors that correspond to the input of the controller being used.
For inductive proximity sensors: Use switch lug
è
Assembly instructions of the accessory.
Mounting of proximity sensor
Use proximity sensors with sensor bracket (A) in the slot
7
è
assembly instructions for the accessory.
Fig. 8
(A)
7
Avoidance of contamination
Connect sealing air. To do this, remove the cover
1
on the hous
ing and connect compressed air/vacuum.
Fig. 9
1