background image

DGO-...-A-B

Festo DGO-...-A-B 2017-10c English

10

Fitting pneumatic components

Fitting in a vertical or sloping position:

Warning

If there is a pressure failure, the work mass will slide down.
Uncontrolled moving masses can cause injury to people or damage to property
(danger of fingers being squashed).

S

Check whether non-return valves (with control) of type HGL-... are required
here. In this way, you can prevent the work mass from sliding down suddenly.
(work mass = slide mass + mass of the work load)

Setting the slide speed:

S

Screw one-way flow control valves of type GRLA-... into the compressed air
ports.

Other accessories with excessive screw depth L will damage the internal slide
of the DGO-.... Fig. 12 shows the maximum screw depth:

DGO-...

16

20

25

32

40

L

max

4.8 mm

8 mm

7 mm

9 mm

10 mm

Fig. 12

Maximum screw depth L

max

 of the compressed air ports

Controlling the DGO-...:

S

Use 3/2-way valves (in basic position
open) for both compressed air ports.

Fig. 13

Summary of Contents for DGO-xxx-A-B series

Page 1: ...en Operating instructions Pneumatic linear drive DGO A B 8074779 2017 10c 8074781...

Page 2: ...2017 10c 2 Original instructions Symbols Fitting and commissioning to be carried out by qualified personnel only in accordance with the operating instructions Warning Caution Please note Antipollution...

Page 3: ...uct For all available product documentation www festo com pk 1 Operating parts and connections 1 2 3 4 5 6 1 Fastening thread 2 Compressed air port 3 Thread for fastening the work load 4 Lubricating n...

Page 4: ...piston moves back wards and forwards in the tubing By means of a magnet coupling this movement is transferred to the outer slide 3 Application The DGO has been designed for transporting mass loads 4 T...

Page 5: ...observed S Observe the ambient conditions at your location Corrosive elements in the environment e g ozone will reduce the service life of the product S Please comply with national and local safety l...

Page 6: ...nd distortion When the drive is fitted in a vertical position S Make sure that the slide has reached a stable position when it comes to a stand e g the lowest point or secure it with a moveable bolt W...

Page 7: ...so that the tilting torque of force Fax parallel to the movement axis and lever arm a remains low see Fig 8 S Observe the maximum values for radial force Frad see Fig 8 150 200 500 1000 100 50 30 20 1...

Page 8: ...of the load and the speed lies within the permitted range Depending on the size of the work mass the DGO will withstand maximum speeds as shown in the following diagram m kg vver m s vhor m s m kg Fig...

Page 9: ...1 SwitchingPos 2 3 1 Magnet 2 Switching range 3 Proximity switches Fig 10 S Always place the proximity switches in the gaps A and X If the gap is too small this may lead to multiple switching If the...

Page 10: ...d here In this way you can prevent the work mass from sliding down suddenly work mass slide mass mass of the work load Setting the slide speed S Screw one way flow control valves of type GRLA into the...

Page 11: ...up pressurization use start up valve type HEL HEM Commissioning the DGO Warning Make sure that nobody can place his her hand in the path of the moving mass e g by providing a protective grill there a...

Page 12: ...en the slide moves into an end position too quickly or without an air cushion For slow start up pressurization use start up valve type HEL HEM 4 Start a test run 5 Check whether the following settings...

Page 13: ...out striking hard against it 8 Operation Warning Make sure that nobody can place his her hand in the path of the moving mass e g by providing a protective grill there are no objects in its path It mus...

Page 14: ...for forces and torques see Fig 8 and maximum speeds see Fig 9 9 Care and maintenance S Clean the cylinder barrel if required with a soft cloth The following cleaning agents are permitted all non abra...

Page 15: ...trol GRLA HGL Screw connector QS Lubricating grease see chapter 9 12 Eliminating faults Fault Possible cause Remedy Uneven movement of the slide One way flow control valve not fitted correctly If poss...

Page 16: ...1 5 M 22 x 1 5 M 22 x 1 5 M 30 x 1 5 M 38 x 1 5 Compressed air port M 5 M 5 G 1 8 G 1 8 G 1 8 G 1 4 Fastening the load M 5 M 6 M 8 Lubricating nipple DIN 3405 AM 6 Magnetic pull off strength 100 N 160...

Page 17: ...DGO A B Festo DGO A B 2017 10c 17...

Page 18: ...zation is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Ruiter Stra e 82 73734 E...