Festo CPX−SF34 1007NH English
26
Plug on
interlinking block
Pin assignment
interlinking block
CPX−M−GE−EV−S...
CPX−M−GE−EV−Z...
7/8"−5POL
1
2
3
4
5
1: 0 V
VAL
/0 V
OUT
2: 0 V
EL/SEN
3: FE
4: 24 V
EL/SEN
5: 24 V
VAL
/24 V
OUT
1: 0 V
OUT
2: n.c.
3: FE
4: n.c.
5: 24 V
OUT
Push−pull
2 3 4 5
1
1: 24 V
EL/SEN
2: 0 V
EL/SEN
3: 24 V
VAL
/24 V
OUT
4: 0 V
VAL
/0 V
OUT
5: FE
1: n.c.
2: n.c.
3: 24 V
OUT
4: 0 V
OUT
5: FE
V
EL/SEN
Operating voltage for electronics/sensors
V
OUT
Load voltage for outputs
V
VAL
Load voltage for valves
FE
Earth terminal
n.c.: not connected
Example of connection
The following diagram shows as an example the
connection for electric outputs with a system power
supplyand an additional power supply (each with
push−pull plugs).