background image

8071235

CPX-E-CEC-...

Controller

8071235
2018-09
[8071237]

Description | Function,
Parameterisation

Summary of Contents for CPX-E-CEC Series

Page 1: ...8071235 CPX E CEC Controller 8071235 2018 09 8071237 Description Function Parameterisation...

Page 2: ...Translation of the original instructions CODESYS EtherCAT MODBUS are registered trademarks of the respective trademark owners in certain countries 2 Festo CPX E CEC 2018 09...

Page 3: ...8 2 6 Connecting components 8 2 6 1 Operating voltage supply 8 2 6 2 Network connections 9 2 7 Additional functions 9 2 7 1 FTP server 9 2 7 2 Web server 9 2 7 3 Temperature sensor 9 2 7 4 Real time c...

Page 4: ...rmation on the use and safe usage of the product Documentation of the components in automation system CPX E and the connected peripherals Information on using the components Online help for CODESYS V3...

Page 5: ...iate device opens the Festo Support Portal with the information appropriate for the product Alternatively the Product Key 11 digit alphanumeric code on the product labelling can be entered in the sear...

Page 6: ...in the higher order controller 2 2 Internal address assignment In addition to the controller CPX E CEC a maximum of 10 modules is permitted in one automation sys tem CPX E The address space of an auto...

Page 7: ...Ethernet ETH Fig 2 Product design 2 4 Display components 1 Module specific LED indicators Operation Run green Connection data traffic Ethernet LA ETH green EtherCAT connection data traffic LA EC green...

Page 8: ...not be started using CODESYS A CODESYS boot application cannot be started Run Stop A project that is running will be stopped Stop Run A project that was stopped using the run stop switch will be conti...

Page 9: ...The integrated web server provides read access to the key parameters and diagnostic functions of the automation system CPX E 2 8 3 Diagnostics via web server 2 7 3 Temperature sensor The controller ha...

Page 10: ...ctions or errors are displayed directly on a PC meaning that diagnostics is also possible from a higher automation level Online help for soft ware EtherCAT Diagnostics as part of the EtherCAT function...

Page 11: ...Run Ethernet interfaces LA ETH LED green Meaning Remedy Lit Network connection established Status Link Flashing Network connection established Status Activity Off No network connection Check network...

Page 12: ...O access Diagnostic information can be requested from lower order EtherCAT devices using SDO access Diagnostics via diagnostics history The most recent diagnostic messages from lower order EtherCAT de...

Page 13: ...4 New message available BOOL RO P 5 Flags U16 0x0000 RW 0x10F3 6 70 Subindex 006 070 BYTE 23 RO 1 RO read only RW read write RO P read only PDO mappable Tab 13 Structure of diagnostics object 0x10F3...

Page 14: ...3 Text ID 02 37 Reference to ESI file with the clear text of the diagnostic message TextId x3702 4 Time stamp 1F C5 9D 61 31 00 00 00 Local time stamp time since controller start 5 Flag parameter 1 0...

Page 15: ...diagnostic messages 2 operating modes are available for processing diagnostic messages Overwrite mode When the number of diagnostic messages reaches 20 old diagnostic messages are overwritten Acknowl...

Page 16: ...at the outputs 23 30 Load dump wire break 31 20 Input voltage too low 33 20 Output voltage too low 50 00 Hardware error all errors 128 Tab 20 Emergency message error code byte 1 byte 0 Emergency messa...

Page 17: ...f the module with diagnostic message Tab 23 Emergency message CPX module number byte 4 Emergency message CPX error number byte 5 Bit Meaning Explanation 0 7 CPX error number CPX error number1 1 Descri...

Page 18: ...via the network 2 Adjusts network settings 3 Open the IP address of the controller in a web browser IP address of controller 192 168 0 1 factory setting The IP address of the controller can be read fr...

Page 19: ...about the controller manufacturer CODESYS Information on the CODESYS licence for the controller 3 Parameterisation The behaviour of the automation system CPX E can be set using the following paramete...

Page 20: ...ntively with Power On Run stop filter 1 Run stop filter 2 Error end filter Error number filter Module channel filter Module number Channel number Error number You can find detailed information in the...

Page 21: ...ion in accord ance with EN 60529 IP20 Protection against electric shock Protection against direct and indirect contact in accordance with IEC 60204 1 through the use of PELV circuits protected extra l...

Page 22: ...Network specific data Protocol EtherCAT Transmission rate Mbps 100 Crossover detection Auto MDI MDI X Maximum cable length per segment m 100 Cable specification Cable type Ethernet twisted pair cable...

Page 23: ......

Page 24: ...ization is prohibited Offenders will be liable for damages All rights reserved in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG 73734 Esslingen Ruiter S...