1. Parts list
10649d_1
1
Basic valve
CPVSC1-M/K/N/D-…
2
Basic valve
CPVSC1-J-…
10649d_7
3
Retaining screws
M1.6 x 15
4
Solenoid valve
MHA1-M…H-3/2G-0.6-…C
2. Fitting the solenoid valve
4
10649d_2
•
Place the solenoid
valve
4
onto the basic
valve
1
/
2
as shown.
•
Tighten screws
3
.
Note here the permitted
tightening torque M
A
.
3. Fitting the basic valve CPVSC1-…-M5…
10649d_3
5
Blanking plug
B-M5 (pre-assembled)
6
Push-in fitting
QS…-M5-5/32-…
7
Push-in fitting
QS…-M5-1/8-…
10649d_6
•
Leave the pre-assembled
blanking plugs
5
fitted.
Do not remove!
•
Select the appropriate
push-in fittings with M5
thread. E.g. push-in fit-
ting
6
or
7
.
•
Screw in the push-in
fittings. Note here the
permitted tightening
torque M
A
.
4. Fitting the basic valve CPVSC1-…-QX…
10649d_4
8
Blanking plug
QSB-M8x0.5
(pre-assembled)
9
Push-in fitting
QSIMG-M-4-X (
@
4 mm)
(pre-assembled)
aJ
Push-in fitting
QSIMG-M-3-X (
@
3 mm)
10649d_5
•
Leave the pre-assembled
blanking plugs
8
fitted.
Do not remove!
In order to use the smaller
push-in fitting
aJ
:
•
Unscrew the pre-
assembled fittings
9
for
tubing
@
4 mm.
ß
8
•
Screw in the push-in
fittings
aJ
supplied for
tubing
@
3 mm.
ß
8
Note here the permitted
tightening torque M
A
.
Assembly instructions (en)
711 468 / 2007-01NH
†‡
Solenoid valve
CPVSC1-…-M5… / -…-QX…
Festo SE
& Co. KG
Postfach
73726 Esslingen
++49/(0)711/347-0
www.festo.com
1
2
3
4
4
3
4
1
4
2
3
3
1
5
2
6
7 6 6
7
M
A
= 1.2 Nm
_
20%
1
8
2
9
aJ 9
9
aJ
M
A
= 0.8 Nm - 20%
5
7
6
8
9
aJ