background image

6

Commissioning

Information on commissioning 

è

 Description CECC.

7

Accessories

è

 www.festo.com/catalogue

8

Technical data

CECC-...

D

LK

S

Operating  voltage X1

19.2 VDC

 

 

30.0 VDC

20.4 VDC

 

 

30.0 VDV

Nominal current consumption at
24 V DC

100 mA

Ambient temperature

0 °C

 

 

55 °C

Storage temperature

–25°C

 

 

+70°C

Relative humidity

95 %, non-condensing

Degree of protection

IP20 (use in inside spaces)

Protection class

III

Dimensions

Length x width x height

130 mm x106 mm x48.15 mm

Product weight

200 g

Resistance test

Against vibration

In accordance with EN 61131-2

Against shock

In accordance with EN 61131-2

Electrical connection technology I/O

Socket strip, grid 3.5 mm

Status displays

LED

High-speed digital counter inputs X2.0 and X2.1

Number

2

Switching frequency

180 kHz

Signal delay (debounce time)

1 μs, factory setting, configurable with CODESYS

Digital inputs X2.2 …

 

X2.7 and X3.0 …

 

X3.5

Number

12

Switching frequency

1 kHz

Signal delay (debounce time)

3 ms, factory setting, configurable with CODESYS

All digital inputs X2 and X3

Switching logic

Positive logic (PNP)

Input voltage

24 VDC

Nominal value for TRUE

15 VDC

Nominal value for FALSE

5 VDC

Disconnection

Digital inputs from the internal
switching logic of the CECC

Galvanically separated

External power supply of
the interface from the operating
voltage supply of the CECC

Galvanically separated

Status indication

LED

Permissible connecting cable length

30 m

Digital outputs X4

Number

8

Switching logic

Positive logic (PNP)

Contact

Transistor

Output voltage

24VDC

Output current

500 mA

Disconnection

Digital outputs from the internal
switching logic of the CECC

Galvanically separated

External power supply of
the interface from the operating
voltage supply of the CECC

Galvanically separated

Switching frequency

1 kHz

Short-circuit proof

Yes

Fieldbus interface X6

Type

CAN bus

Connection technology

Plug, Sub-D, 9-pin

Transmission rate

10, 20, 50, 100, 125, 250, 500, 800, 1000 kBit/s
configurable with CODESYS

Disconnection

Signal lines of the interface from
the internal switching logic of the
CECC

Galvanically separated

Internal power supply of the
interface from the operating
voltage supply of the CECC

Galvanically separated

CECC-...

D

LK

S

USB interface X7

USB1.1

Ethernet interface X8

Connector plug

RJ45

Quantity

1

Transmission speed

10/100 Mbit/s

Suppor ted protocols

TCP/IP, EasyIP, ModbusTCP

IO-Link-interfaces

X12…X16

X15…X16

Protocol

IO-Link Device  Port: V 1.0
IO-Link Master  Port: V 1.1

Connection technology, plug

IO-Link Device  Port: 3-pin
IO-Link Master  Port: 5-pin

Communication mode

Can be configured via software
IO-Link Device  Port: COM1, COM2, COM3
IO-Link Master  Port: SIO, COM1, COM2, COM3

Permitted cable length

20 m

Port type

IO-Link Device  Port: A
IO-Link Master  Port: B

Number of ports

1 IO-Link Device  Port

4 IO-Link Master
Ports

1 IO-Link Master  Port

Output current operating voltage
(L+, L-)

≤ 200 mA/IO-Link Port

Output current load voltage (24, 0)

≤ 3.5 A/IO-Link Master  Port

Communication

C/Q LED green
C/Q LED red

Ready status display

L+ LED green on
L+ LED green off

Process data width OUT

IO-Link Master: 2

 

 

32 byte, can be

parameterised

Process data width IN

IO-Link Master: 2

 

 

32 byte, can be

parameterised

Storage

2 kByte/IO-Link Master Port

Minimum cycle time

IO-Link Device Port: 3.2 ms
IO-Link Master  Port: 5 ms

Device ID

0x550000, 0x550001, 0x550002, 0x550003,
0x550004

Serial interface modules

X12…X14

Type

2xRS232
1xRS485-A/422-A

Connection technology

Plug connector

Transmission rate

300…

 

375000 bit/s

Encoder interface

X14

Resolution

32 bit

Signal range

5 V, differential (RS422)

Maximum input frequency

1000 kHz

Operating voltage supply
for encoders

5 VDC

Programming languages

In accordance with IEC61131-3 AS, AWL, FUP, KOP, ST

Programming software

CODESYS V3pbF

Approvals

RCM mark
cULus - Listed (OL)

UL certification

Contamination level

2

Setup altitude

2000 m

Total power rating of the operating
and load voltage power supplies at
X1, X5 and X11

4.3 A

6 A

1)

Load rating of the operating voltage
supply X1

125 mA

Load rating of the operating voltage
supply of the I/O interfaces X5

4.1 A

Load rating of the load voltage
supply X11

5.875 A

3.5 A

CE marking 

è

 www.festo.com/sp

è

 Declaration of conformity

In accordance with EU EMC  Directive

2),3)

1)

The outputs of the CECC may be loaded only to the extent that the maximum total of input currents at
X1 (V-El.), X5 and X11 (CECC-LK: V-IOL, CECC-S: 24 V DC) is limited to 6 A.

2)

The controller is intended for use in an industrial environment: Outside of industrial environments, e.g.
in commercial and mixed-residential areas, actions to suppress interference may have to be taken.

3)

The controller is classified in zone A in accordance with EN 61131-2:2007.

Fig. 18 Technical data