ID Dx.
Name
Description
01 | 02 | 00014
(16908302)
I²t monitoring: output stage warn-
ing limit
I²t monitoring: output stage warning limit
01 | 02 | 00015
(16908303)
I²t monitoring: output stage error
limit
I²t monitoring: output stage error limit
01 | 02 | 00016
(16908304)
I²t monitoring: output stage v0
warning limit
I²t monitoring: output stage in standstill warn-
ing limit
01 | 02 | 00017
(16908305)
I²t monitoring: output stage v0
error limit
I²t monitoring: output stage in standstill error
limit
Tab. 158 Diagnostic messages of “I²t monitoring of the power output stage”
3.4.1.1
CiA 402
Objects of “I²t monitoring of the power output stage”
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
637
0x216A.07
Scaling factor start value I²t monitoring power
output stage
FLOAT32
638
0x216A.08
Limit value I²t monitoring power output stage
FLOAT32
639
0x216A.09
Scaling factor maximum value after switching
on
FLOAT32
6310
0x216A.0A
Actual value I²t monitoring power output stage FLOAT32
6311
0x216A.0B
Scaling factor warning limit I²t monitoring
power output stage
FLOAT32
6313
0x216A.0C
Scaling factor start value I²t monitoring power
output stage at standstill
FLOAT32
6314
0x216A.0D
Limit value I²t monitoring power output stage
at standstill
FLOAT32
6315
0x216A.0E
Scaling factor maximum value after drive at
standstill
FLOAT32
6316
0x216A.0F
Actual value I²t monitoring power output stage
at standstill
FLOAT32
6317
0x216A.10
Scaling factor warning limit I²t monitoring
drive at standstill
FLOAT32
6332
0x216A.1E
Actual value relative I²t monitoring of power
output stage to limit
FLOAT32
Product configuration
187
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW