Festo — CMMT-ST-C8-1C-...-S0 — 2021-04b
Technical data
55
10.2.6
Standard Ethernet [X18], parameterisation interface
Standard Ethernet [X18], parameterisation interface
Design
To IEEE 802.3:2012-00
1)
Connection design
RJ45
Transmission rate
[Mbit/s] 10/100 (full/half duplex)
Supported protocols
TCP/IP
IP address set at fac-
tory (presetting)
192.168.0.1
1) Restriction: The interface is galvanically isolated and intended for use with limited cable lengths.
Tab. 79: Standard Ethernet [X18]
10.2.7
Real-time Ethernet [XF1 IN], [XF2 OUT]
Real-time Ethernet [XF1 IN], [XF2 OUT]
Design
RTE communication, physical level in accordance with
IEEE 802.3: 2012-00
1)
Bus connection design
[XF1 IN]
RJ45
Bus connection design
[XF2 OUT]
RJ45
Max. transmission rate [Mbit/s] 100
Bus protocol EtherCAT: CMMT-ST-...-EC
Protocol
–
CoE (CANopen over EtherCAT)
–
EoE (Ethernet over EtherCATEtherCAT)
–
FoE (File Access over EtherCAT)
Communication profile
–
CiA 402
Bus protocol EtherNet/IP: CMMT-ST-...-EP
Protocol
–
Implicit messaging
–
Explicit messaging
Bus protocol PROFINET: CMMT-ST-...-PN
Protocol
–
PROFINET RT
–
PROFINET IRT
Drive profile
–
PROFIdrive
1) Restriction: the interface is galvanically isolated and intended for use with limited cable lengths.
Tab. 80: Real-time Ethernet [XF1 IN], [XF2 OUT]