![Festo CMMS-ST-*-G2 Series Assembly And Installation Manual Download Page 25](http://html1.mh-extra.com/html/festo/cmms-st-g2-series/cmms-st-g2-series_assembly-and-installation-manual_2283131025.webp)
3. Product description
Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH
25
•
2-channel oscilloscope function
•
English and German
3.3
Interfaces
3.3.1
Control interfaces
Control interfaces
Signal type
Analogue Analogue signal
A/B - tracking signals (RS422)
CLK/DIR – pulse/direction
Frequency signals
CW/CCW – pulse
I/O
Digital I/O – signals for control of record selection and jog mode
CANopen (FHPP/CiA DSP 402)
PROFIBUS-DP (FHPP)
Fieldbus
DeviceNet (FHPP)
Table
3.1 Control interfaces
3.3.2
Overview of interfaces
Setpoint interface /
Interface
Setpoint
specification via
Function Operating
mode Reference
Analogue X1
(±
10V) Analogue
setpoint
specification
Speed control Torque
control
Pulse / direction of
interface
X1 (24 V / Mode 3)
X10 (5 V)
CW/CCW
CLK/DIR
Synchronisation
A/B s
I/O mode 3 (start
synchronisation)
X10 (5 V)
Master/slave
(slave)
Synchronisation
I/O
X1 (24V /
Mode 0/1/2)
Record
selection
Jog mode
Linked positio-
ning records
Positioning controller