![Festo CMMS-ST-C8-7 Assembly And Installation Manual Download Page 24](http://html1.mh-extra.com/html/festo/cmms-st-c8-7/cmms-st-c8-7_assembly-and-installation-manual_2283132024.webp)
3. Product description
24
Festo.P.BE-CMMS-ST-HW-EN 0903b
3.3
Interfaces
3.3.1
Control interfaces
Control interfaces
Signal type
Analogue
Analogue signal
Frequency signals
A/B – tracking signals (RS422)
CLK/DIR – pulse/direction
CW/CCW – pulse
I/O
Digital I/O – signals for control of record selection and jog mode
Field bus
CANopen (FHPP/DS402)
PROFIBUS-DP (FHPP)
DeviceNet (FHPP)
Tab. 3.1 Control interfaces
3.3.2
Overview of interfaces
Setpoint interface /
Interface
Setpoint
specification via
Function
Operating mode
Reference
Analogue
X1 (±10 V)
Analogue setpoint
specification
Speed control Torque
control
1.1.1
Tab. 6.2 ff
Pulse / direction of
interface
X1 (24 V / Mode 3)
X10 (5 V)
CW/CCW
CLK/DIR
Synchronization
A/B s
I/O mode 3 (start
synchronization)
X10 (5 V)
Master/slave (slave)
Synchronization
I/O
X1 (24 V /
Mode 0/1/2)
Record selection
Jog mode
Linked positioning
records
Positioning controller 3.3.5
Tab. 6.2 ff
CANopen field bus
X4 (CAN)
Direct application
Homing run
Jog mode
Record selection
Interpolated position
mode (DS402)
Speed control
Torque control
Positioning control
Tab. 3.2 Interfaces