6. Electrical installation
96
Festo.P.BE-CMMS-ST-HW-EN 0903b
Pin
Designation
Value
Mode = 3 – Synchronization
1
AGND
0 V
Screen for analogue signals
2
DIN12
Slave synchronization "1"
3
DIN10
4
+VREF
+10 V ±4 %
Reference output for setpoint potentiometer
5
Free
6
GND24
Reference potential for digital inputs and outputs
7
DIN1
8
DIN3
24 V
Direction_24 / CCW
9
DIN5
Controller release (high active)
10
DIN7
Limit switch 1
11
DIN9
Slave synchronization "1"
12
DOUT1
24 V 100 mA Output freely programmable - default motion complete (high active)
13
DOUT3
24 V 100 mA Output freely programmable - default error (low active)
14
AGND
0 V
Reference potential for the analogue signals
15
DIN13
Stop input (low active)
16
DIN11
17
AMON0
+10 V ±4 %
Analogue monitor output 0
18
+24 V
24 V 100 mA 24 V feed-in feed-out
19
DIN0
20
DIN2
24 V
Pulse_24 / CW
21
DIN4
End stage enable (high active)
22
DIN6
Limit switch 0
23
DIN8
Start synchronization
24
DOUT0
24 V 100 mA Ready for operation output (high active)
25
DOUT2
24 V 100 mA Setpoint reached output (high active)
Tab. 6.5: Pin allocation: I/O interface [X1] Mode 3