Assembly instructions (Original: de)
8035903
1405a
†‡
Switch/safety module
CAMC-DS-M1/CAMC-G-S...
Festo AG & Co. KG
Postfach
73726 Esslingen
Germany
+49 711 347-0
www.festo.com
1.
Parts list
17303d_1
1
Switch/safety
module
CAMC-...
(1x)
(A) CAMC-DS-M1
(B) CAMC-G-S...
11375d_5
Not included in delivery:
2
Motor
controller
CMMP-AS-...-M3
(Z) Slot
EXT3
(1x)
2.
Intended use
Switch/safety module CAMC:
Mounting in the slot (Z).
3.
Safety instructions and notes on mounting
Warning
Electric voltage.
Injury (death) due to electric shock.
Switch off power supply before assembly work.
Wait 5 minutes. Only then is motor controller
2
completely discharged.
Observe other safety instructions (
applicable documents).
Note
Electrostatically sensitive devices.
Malfunction of the internal electronics due to electrostatic discharge.
Do not touch the printed circuit board.
Information
Applicable documents
Description of the motor controller: CMMP-AS-...-M3
4.
Mounting
17303d_7
At the slot (Z):
Remove protective foil (C).
17303d_5
Slide module
1
into the
guides.
Tighten screws (K).
Observe the tightening
torque.
Result: Front plate (L) has
conducting contact with the
housing (M).
0.4 Nm
_
20 %
2
C
1
2
K
L
M
B
1
A
Z
2