Operating and Ambient Conditions
Individual valve fastened with screws: SG2
Individual valve on H-rail: SG1
Linking of max. 3 valves with lateral screw mounting: SG2
Vibration (part 2-6)
Linking of max. 5 valves with lateral screw mounting: SG1
Individual valve fastened with screws: SG2
Individual valve on H-rail: SG1
Linking of max. 3 valves with lateral screw mounting: SG2
Shock (part 2 – 27)
Linking of max. 5 valves with lateral screw mounting: SG1
Tab. 13 Operating and Ambient Conditions
Features of severity level (SL)
Vibration load
Frequency range [Hz]
Acceleration [m/s
2
]
Deflection [mm]
SL1
SL2
SL1
SL2
SL1
SL2
2
…
8
2
…
8
–
–
±
3.5
±
3.5
8
…
27
8
…
27
10
10
–
–
27
…
58
27
…
60
–
–
±
0.15
±
0.35
58
…
160
60
…
160
20
50
–
–
160
…
200
160
…
200
10
10
–
–
Shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
SL1
SL2
SL1
SL2
SL1
SL2
±
150
±
300
11
11
5
5
Continuous shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
±
150
6
1000
Tab. 14 Features of severity level (SL)
Pneumatic Characteristic Values
Input pressure at (1)
1)
Operating pressure at (1)
2)
Product type
[MPa]
[bar]
[MPa]
[bar]
VPPI -...- 1V0H -...
0
…
0.6
0
…
6
0
…
0.2
0
…
2
Technical Data
24