Festo CP−FB6−E 0802f English
25
Ty
pe
CP F
B
6
−
E
Pi
n
1
Operating voltage connection for
electronics (eletronics/inputs)
Rated value
Tolerance
Current consumption of the
CP−FB6−E
Current consumption of the complete
CP system
24 V DC (protected against
incorrect polarity)
20.4...26.4 V
Max. 250 mA
See manual CP system",
current consumption table
Pi
n
2
Load voltage connection
(outputs/valves)
Rated value
Tolerance
Current consumption
24 V DC (protected against
incorrect polarity)
20.4...26.4 V
Sum of all switched−on CP
solenoid valves; see manual
CP pneumatics"
R
es
i
du
al ri
pp
l
e
4 Vpp (within tolerance)
Detailed information on the CP FB6−E can be found in the
manual P.BE−CP−FB6−E−.. .