3URGXFWVSHFLILFDWLRQV

Type

SMEO-4..-...

CRSMEO-4 -...

K-LED-230

..U-K-LED-230

..U-K-LED-24

..U-S-LED-24B

K-LED-24 B

S-LED-24B

...K-LED-24

Part no.

15 709

150 011

36 198

151 526

164 595

150 849

161 775

Housing

straight

2x angled (U-shape)

straight

Perm. operating voltage

AC/DC 12...230* V

AC/DC 12 ... 27 V

AC/DC 12 ... 30 V

Voltage drop at 
proximity switch

max. 4 V

None

Permitted  switching current

max. 500 mA (ohmic load; with regard to the max. switching capacity and the perm. operating voltage)

Service classification
ohmic load (AC12/DC12)
inductive load (AC14/DC13)

bei AC 230 V 

bei DC 230 V 

0,04 A**

0,04 A**

0,024 A**

0,04 A**

Max. switching output

10 W (ohmic load)

Max. switching frequency

500 Hz

800 Hz

Max. switching time

2 ms

0,5 ms

Permitted temperature range

-20 ... +60° C 

CE-compliance 
- electromag. compatibility

Immunity to interference as per DIN EN 50082-2
Interference emission as per DIN EN 50081-1

- low voltage regulation

according to 73/23/EWG

Materials

POM, PC,
PVC

PC, PA, PET,
PVC, TPE-O

PC, PA,
PET,  PVC,
TPE-O

PC, PA,  PET,
Brass
(chromium-
plated)

PC, PP,
PVC

PC, PP,
Brass
(chromium-
plated)

PC, PP, 
TPE-O

*) Design operating voltage **) Design operating current

)LJ

9908d

D/GB 15

Summary of Contents for 150011

Page 1: ...0 2 8 560 2 Einbau und Inbetriebnahme nur von autorisiertem Fachpersonal gem Bedienungsanleitung Fitting and commissioning to be carried out by qualified personnel only in accordance with the operatin...

Page 2: ...e 230 V AC 115 V AC input cards of programmable logic controllers without a current limiting resi stor The PLC input capacity effects too great a switch on capacity for the SMEO 4 U The SMEO 4 U is us...

Page 3: ...en Beachten Sie die Vorschriften der Berufsgenossenschaft des Techn berwachungsvereins die VDE Bestimmungen oder entsprechende nationale Bestimmungen The internal reed contact is actuated magnetically...

Page 4: ...urch auftretende Zugkr fte am SME O 4 kann sich der Befesti gungsbausatz verschieben Remove all packaging such as protec tive wax foils caps and cardboard The individual materials can be dispo sed of...

Page 5: ...nkel zur Zylinder au enwand Schwenk bereich ca 90 bei fixem Schaltpunkt mit dem asymmetri schen Geh useteil 2 nach oben Kon taktver meidung mit der Zylinder oberfl che LOG SMEO 4 SMEO 4U CRSMEO 4 toge...

Page 6: ...elding Protect the SMEO 4 U against out side influences with a ferritic screen ing e g with transformer sheet steel The screening must not lie in the im mediate vicinity of the SMEO 4 U SMEO4 SMEO4 LO...

Page 7: ...n this way you can minimize the dan ger of interference from other so lenoids Check the spacing of the cylinders for each fitting arrangement The following minimum distances must be observed X X 1 2 L...

Page 8: ...tigkeit PELV Schaltnetzteile nach EN 60950 VDE 0805 sind zul ssig OHFWULFDO The SMEO 4 U with two wire con nection should only be used under load Otherwise there will be a short circuit If the SMEO 4...

Page 9: ...ighten the strain relief nuts of the sockets with max 0 3 Nm With SMEO 4 U in cable version make sure that the cables are not squashed not bent not stretched See Technical specifications for the permi...

Page 10: ...tat R ckmeldung Entlang der Zylinderachse zun chst bis er umschaltet dann einige Millimeter weiter in die gleiche Richtung erkennbar durch Schaltzustands anzeige LED oder Messen des Signals am Schalt...

Page 11: ...sto eher wird die Lebensdauer grenze erreicht Stellen Sie sicher da keine Zug kr fte auf das Anschlu kabel des SME O 4 ausge bt werden Tighten the locking screw A max 0 5 Nm Start a test run Check to...

Page 12: ...peters ure HNO3 Peressigs ure CH3CO3H Hei dampf H2O LOG Cleaning agent Chemical symbol Soda lye NaOH Sodium hypochlorite NaOCl Phosphoric acid H3PO4 Nitric acid HNO3 Per acid CH3CO3H Superheated steam...

Page 13: ...it Befestigungsbau satz siehe Zubeh r Schutzart IP 67 nach DIN VDE 470 bei richtig montierter Dose mit Kabel Werkstoffe Befestigungsbau satz SMBR POM Messing St CRSMBR PP St CRSMB St zul Kabel Biegera...

Page 14: ...Betriebsspannung Gebrauchskategorie ohmsche Last AC12 DC12 induktive Last AC14 DC13 bei AC 230 V bei DC 230 V 0 04 A 0 04 A 0 024 A 0 04 A max Schaltleistung 10 W ohmsche Last max Schaltfrequenz 500 H...

Page 15: ...age Service classification ohmic load AC12 DC12 inductive load AC14 DC13 bei AC 230 V bei DC 230 V 0 04 A 0 04 A 0 024 A 0 04 A Max switching output 10 W ohmic load Max switching frequency 500 Hz 800...

Page 16: ...lar the right to carry out patent utility model or ornamental design registrations St rung m gliche Ursache Abhilfe CR SMEO 4 U reagiert zu fr h zu sp t St rungseinfl sse Fremdfelder parallele Zylinde...

Reviews: