3URGXFWVSHFLILFVSHFLILFDWLRQV93(ZLWKRXW93(6:
Type
PE-PK-4
PE-PK-3x2-2N
PE-1/8-1N
PE-1/8-2N
VPE-1/8
VPE-1/8-2N
Part no.
7470
13691
6217
7860
12592
12594
Pressure range
0 ... 0.25 bar
0 ... 8 bar
0 ... -0.95 bar
Starting pressure
≤
0.08 bar
≤
2 bar
-0.25
±
0.05 bar
Switch-off pressure
≥
0.01 bar
≥
0.5 bar
≥
-0.1 bar
Overload pressure (brief, static)
at P: max. 8 bar
at P: max. 12 bar
at V: max. 1 bar
Rated operating voltage (V
b
)
250 V AC/DC
Rated operating current (with V
b
)
– ohmic load
– inductive load
at AC 250 V
6 A
2 A
at DC 250 V
0.25 A
0.1 A
Use category
– ohmic load
– small electro-
magnetic load
AC 12/DC 12
AC 14/DC 13
Switching capacity (DC)
Voltage [V DC]:
– resistor load [A]
– inductive load [A
– bulb load [A]
12
6
6
3
24
6
6
2
60
1
0.5
0.6
110
0.5
0.2
0.5
230
0.25
0.1
0.25
Protection class (as per EN 60 529)
IP 00
IP 20 (only in conjunction with protective cap type SPE-B)
Materials Housing
Connections
Diaphragm
Contacts
PET/POM/St
CuZn
CR rubber
Silver contacts
PET/POM/St/GD-AL
CuZn
Urethane rubber
Silver contacts
PET/POM
CuZn
CR rubber
Silver contacts
)LJ
93(6:
9908a
D/GB 18