1.5.5 Exiting Configuration Mode and Saving Configuration Changes
1.5 Configuring the Control Modules
0101-9031-0, Rev. B
19
Genius II Quick Start Guide
15
When the beam is at the position desired for the –longitude limit,
press the Set -Long button.
When all four position limits have been set, the main controller’s touch
screen will appear similar to that shown in Figure 21.
Figure 21 Config>Sweep Screen After All Four Limits Are Set
16
Touch the E-Beam button to switch off the beam.
Configuration of the Sweep Control module is now completed. If you have finished configuring all three
control modules, follow the procedure described in section 1.5.5 to exit from Configuration Mode and
save your configuration parameters. However, if you wish to assign specific materials to specific pockets,
follow the instructions provided in section 3.8 of the
Genius II User Manual before exiting from
Configuration mode. Likewise, if you wish to enable the LogIn manager and assign user passcodes and
permissions, follow the instructions provided in section 3.7 of the
Genius II User Manual before
proceeding to section 1.5.5.
1.5.5 Exiting Configuration Mode and Saving Configuration Changes
Configuration changes are automatically saved when you exit from Configuration Mode. To do so,
perform the procedure described below.
Step
Action
1
Touch the Menu Bar’s Config button to display the Auxiliary Menu,
which is shown in Figure 22. That illustration shows the Config>Sweep
screen as it appears after configuration of the Sweep Control module
is completed. However, you can exit from Configuration mode from
any Configuration Mode screen.