ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE

EN

 - 

INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

Summary of Contents for SKY C 11 B

Page 1: ...01 01 2018 SKY C B 595 a4 A B 195 95 11 CB 14 CB A 295 335 Modello 7 9 8 a4 Ø 110 130 B 210 250 8 7 9 60 100 IT ISTRUZIONE PER L USO L INSTALLAZIONE E LA MANUTENZIONE EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Page 2: ...ERICOLO DI USTIONI Verifiche e operazioni preliminari 1 Accertarsi che i rubinetti dell acqua calda siano chiusi 2 Aprire il rubinetto di alimentazione del gas allo scaldabagno situato sull allaccia mento del gas all apparecchio 3 Verificare che le batterie da 1 5 V siano inserite nella rispettiva sede con la polarità corretta e Per la loro sostituzione vedere Sostituzione batterie a pag 5 4 Verif...

Page 3: ...OSSICAZIONE LEGGERE LE ISTRUZIONI DI INSTALLAZIONE E DI MANUTENZIONE PRI MA DI INSTALLARE L APPARECCHIO RISPETTARE ANCHE LE INTRUZIONI DI PROGETTAZIONE Il tubo di raccordo alla canna fumaria deve avere un diametro non inferiore a quello di attacco sull antirefouleur A partire dall antirefouleur deve avere un tratto verticale di lunghezza non infe riore a mezzo metro Per quanto riguarda il dimensio...

Page 4: ...re lo scaldabagno Verificare la tenuta dell impianto gas Riempire l impianto idraulico ed assicurare un completo sfiato dell aria contenuta nello scaldabagno e nell impianto Verificare che non vi siano perdite di acqua nell impianto o nell apparecchio Verificare che il valore di pressione gas sia quello richiesto Verificare che non vi siano liquidi o materiali infiammabili nelle immediate vicinanz...

Page 5: ...esentare perdite Il bruciatore e lo scambiatore devono essere puliti ed esenti da incrostazioni Per l eventuale pulizia non usare prodotti chimici o spazzole di acciaio Gli elettrodi devono essere liberi da incrostazioni e correttamente posizionati fig 13 Posizionamento elettrodi Gli impianti gas e acqua devono essere a tenuta La portata gas e la pressione devono corrispondere a quanto indicato ne...

Page 6: ...a t 50 C l min 5 5 6 8 D Grado protezione IP X5D X5D Peso a vuoto kg 11 12 Tipo di apparecchio B11BS PIN CE 0461CL0984 DK K z ϭϭ ĐŚĞĚĂ ƉƌŽĚŽƚƚŽ ƌW D Ϭ ϬϬϬ ϳϰ ϴ ϰϰϳ D y ϱϵ ϭϰϱ ϲ Ϭ ůĞŵĞŶƚŽ WƌŽĨŝůŽ Ěŝ ĐĂƌŝĐŽ ĚŝĐŚŝĂƌĂƚŽ ůĂƐƐĞ Ěŝ ĞĨĨŝĐŝĞŶnjĂ ĞŶĞƌŐĞƚŝĐĂ Ěŝ ƌŝƐĐĂůĚĂŵĞŶƚŽ ĚĞůů ĂĐƋƵĂ ŽŶƐƵŵŽ ŐŝŽƌŶĂůŝĞƌŽ Ěŝ ĞŶĞƌŐŝĂ ĞůĞƚƚƌŝĐĂ ŽŶƐƵŵŽ ĂŶŶƵŽ Ěŝ ĞŶĞƌŐŝĂ ĞůĞƚƚƌŝĐĂ ĨĨŝĐŝĞŶnjĂ ĞŶĞƌŐĞƚŝĐĂ Ěŝ ƌŝƐĐĂůĚĂŵĞŶƚŽ ĚĞůů ĂĐƋƵĂ ŽŶ...

Page 7: ...SKY C B 7 IT cod 3541C705 Rev 01 01 2018 5 4 Schema elettrico fig 16 82 188 Marking 7 8 9 10 11 12 13 14 15 16 6 5 4 3 2 1 4 3 2 1 126 49 3 2 1 DISPLAY 44 359 3 2 1 358 1 2 _ 372 ON OFF 42 83 ...

Page 8: ...ƐƐĂ ƐĐůƵƐŝŽŶŝ ŽŶŽ ĞƐĐůƵƐŝ ĚĂůůĂ ƉƌĞƐĞŶƚĞ ŐĂƌĂŶnjŝĂ ŝ ĚŝĨĞƫ Ěŝ ĐŽŶĨŽƌŵŝƚă ĐĂƵƐĂƟ ĚĂ ͻ ƚƌĂƐƉŽƌƚŽ ŶŽŶ ĞīĞƩƵĂƚŽ Ă ĐƵƌĂ ĚĞůů ĂnjŝĞŶĚĂ ƉƌŽĚƵƩƌŝĐĞ ͻ ĂŶŽƌŵĂůŝƚă Ž ĂŶŽŵĂůŝĞ Ěŝ ƋƵĂůƐŝĂƐŝ ŐĞŶĞƌĞ ŶĞůů ĂůŝŵĞŶƚĂnjŝŽŶĞ ĚĞŐůŝ ŝŵƉŝĂŶƟ ŝĚƌĂƵůŝĐŝ ĞůĞƩƌŝĐŝ Ěŝ ĞƌŽŐĂnjŝŽŶĞ ĚĞů ĐŽŵďƵƐƟďŝůĞ Ěŝ ĐĂŵŝŶŝ Ğ Ž ƐĐĂƌŝĐŚŝ ͻ ĐĂůĐĂƌĞ ŝŶĂĚĞŐƵĂƟ ƚƌĂƩĂŵĞŶƟ ĚĞůů ĂĐƋƵĂ Ğ Ž ƚƌĂƩĂŵĞŶƟ ĚŝƐŝŶĐƌŽƐƚĂŶƟ ĞƌƌŽŶĞĂŵĞŶƚĞ ĞīĞƩƵĂƟ ͻ ĐŽƌƌŽƐŝŽŶŝ ĐĂƵƐĂƚĞ ĚĂ...

Page 9: ...ake sure the hot water taps are closed 2 Open the water heater gas supply cock located on its gas connection 3 Make sure the 1 5 V batteries are properly fitted with the correct polarity and For their replacement see Replacing batteries on page 12 4 Also make sure the batteries have enough charge for water heater operation Lighting Turn the knob to the required water heating level fig 2 Lighting T...

Page 10: ...OF SUFFOCATION OR INTOXICATION READ THE INSTALLATION AND MAINTENANCE INSTRUCTIONS BE FORE INSTALLING THE UNIT ALSO FOLLOW THE DESIGN INSTRUCTIONS The diameter of the flue connection pipe must not be less than that of the connection on the anti backflow device Starting from the anti backflow device it must have a vertical section at least 50 cm long The current regulations must be complied with reg...

Page 11: ... 4 2 Commissioning Before lighting the water heater Check the tightness of the gas system Fill the hydraulic system and make sure the air in the water heater and system is completely vented Make sure there are no water leaks in the system and unit Check the correct gas pressure value Make sure there are no flammable liquids or materials in the immediate vicinity of the water heater IF THE ABOVE IN...

Page 12: ...acles and leaks The burner and exchanger must be clean and free of deposits For possible clean ing do not use chemical products or wire brushes The electrodes must be free of deposits and correctly positioned fig 13 Electrode positioning The gas and water systems must be tight The gas flow and pressure must match that given in the respective tables 5 TECHNICAL DATA AND CHARACTERISTICS Table 3 Lege...

Page 13: ...ure bar 0 20 0 20 DHW flow rate t 25 C l min 11 0 14 0 DHW flow rate t 50 C l min 5 5 6 8 D Protection rating IP X5D X5D Empty weight kg 11 12 Type of unit B11BS PIN CE 0461CL0984 DK z ϭϭ ƌW ƉƌŽĚƵĐƚ ĨŝĐŚĞ D Ϭ ϬϬϬ ϳϰ ϴ ϰϰϳ D y ϱϵ ϭϰϱ ϲ Ϭ ƚĞŵ ĞĐůĂƌĞĚ ůŽĂĚ ƉƌŽĨŝůĞ tĂƚĞƌ ŚĞĂƚŝŶŐ ĞŶĞƌŐLJ ĞĨĨŝĐŝĞŶĐLJ ĐůĂƐƐ ĨƌŽŵ н ƚŽ Ϳ ĂŝůLJ ĞůĞĐƚƌŝĐŝƚLJ ĐŽŶƐƵŵƉƚŝŽŶ ŶŶƵĂů ĞůĞĐƚƌŝĐŝƚLJ ĐŽŶƐƵŵƉƚŝŽŶ tĂƚĞƌ ŚĞĂƚŝŶŐ ĞŶĞƌŐLJ ĞĨĨŝĐŝĞŶ...

Page 14: ...SKY C B 14 EN cod 3541C705 Rev 01 01 2018 5 4 Wiring diagram fig 16 82 188 Marking 7 8 9 10 11 12 13 14 15 16 6 5 4 3 2 1 4 3 2 1 126 49 3 2 1 DISPLAY 44 359 3 2 1 358 1 2 _ 372 ON OFF 42 83 ...