Ferroli ROMEO W RF Manual Download Page 2

EN

Temperature unit of measure selection

Follow the instructions given below to use the Remote Control in °C or in °F.

1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   7 times.   

4. The display shows parameter P6.

 

Set to 0 using the buttons 

 to select °C.

 

Set to 1 using the buttons 

 to select °F.

5. Press any other button to exit the menu.

Room temperature reading correction

Follow the instructions given below to correct the room temperature reading between -2°C and +2°C in 0.1°C steps.

1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   8 times.   

4. The display shows parameter P7.

 

Use the buttons 

 to adjust the parameter in 0.1°C increments.

5. Press any other button to exit the menu.

Telephone contact input

Normal Remote Control operation is ensured as long as the telephone contact remains open. The closing of this 

contact, indicated on the display with the symbols (), can be used to force the Remote Control to switch off heating 

or to set the room temperature to a preset 

fi

 xed value. 

Follow the instructions given below to set the two functions.

1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   9 times.   

4. The display shows parameter P8.

Set to 0 using the buttons 

 to switch off heating when the contact is closed.  

Set to 1 using buttons 

 to adjust room temperature to a preset 

fi

 xed value (by means of parameter 

P9) when the contact is closed.

5. Press the button  . 

 

6. The display shows parameter P9.

Set the room temperature value that the Remote Control will adjust when the contact is closed (if parameter 

P8 is set to 1) by pressing the buttons 

 in 0.1°C increments. By keeping the button pressed the 

temperature will change rapidly.

7. Press any other button to exit the menu.

Modi

fi

 cation of the Remote Control operating mode on opening or closing of the telephone contact can occur in a 

maximum time of 120 seconds.

OTHER FUNCTIONS

Information menu

The remote control can provide the user with information on boiler status. Each press of the button   allows the cyclic display 

of the following information:

T1 - Heating circuit delivery water temperature

T2 - Domestic hot water temperature

T3 - Heating circuit return water temperature (boilers with sensor only)

T4 - Delivery water temperature setpoint calculated by the remote control

P5 - Actual burner power

F6 - Actual fan speed (condensing boilers only)

F7 - Actual DHW 

fl

 owrate (instant hot water boilers with 

fl

 owmeter only)

P8 - Actual system pressure (boilers with pressure sensor only)

 v - Remote control software version

Press any other button to exit the menu.

Power failure

In this case the Bridge RF stops working, because it is electrically fed by the boiler card.
The symbol (

) shown on the Remote Control display starts flashing. If the power is restored within 2 minutes, the symbol 

 

becomes fixed again and RF communication is immediately activated. Otherwise the display activates fault E94 and the symbol 

: once the power is restored, it is necessary to wait about 15 minutes. After which the symbol 

 becomes fixed and RF 

communication is available again.

Diagnostics

The remote control constantly monitors boiler status and signals any faults by activating an alarm icon and a specific fault code: 

for a description of the fault, refer to the boiler documentation.

Certain faults cause permanent shutdowns (indicated with the letter "A"): to reinstate operation just press the RESET button; 

other faults (indicated with the letter "F") cause temporary shutdowns which are automatically reset as soon as the value returns 

within the boiler's normal working range.

Room temperature probe fault

In case of a Remote Control room temperature probe, the display activates fault code E92 and the symbol 

. Heating is 

switched off.

External temperature probe fault

In Sliding Temperature operation and in case of an external temperature probe (optional) fault, the display activates fault code E93 
and the symbol 

. The adjustment temperature become fixed at the "Heating temperature adjustment" value. To eliminate the 

fault, reset the external probe or disable Sliding Temperature adjustment.

RF REMOTE CONTROL INSTALLATION

The RF Remote Control can be wall-mounted or installed on the desk-top support provided; as an 

alternative to wall-mounting, the latter allows the RF Remote Control to be placed on a support 

surface.

The RF Remote Control must be fixed to the wall at a height of approx. 1.5 m from the floor, in 

a place away from entrance doors, windows or heat sources that could affect room temperature. 

Disconnect the power to the boiler before carrying out installation. Remove the front part of the 

RF Remote Control by prising with a screwdriver at points A and B. Then fix the back of the RF 
Remote Control to the wall with the set of screws supplied. Do not insert the batteries: see Step 
1: 

Installation check

 and Step 2: 

Battery installation

.

Refit the front part of the RF Remote Control.

RF BRIDGE INSTALLATION

Disconnect the power to the boiler before carrying out installation. Remove the front part of the 

RF Bridge by prising with a screwdriver at points A and B. Then fix the back of the RF Bridge 

to the wall with the set of screws supplied, running the two wires inside the rectangular hole 

at the bottom (near the terminals): use the "OT" terminals for the electrical connection. If the 

telephone contact (voltage-free contact) has to be connected, use the "GSM" terminals. Refit the 

front part of the RF Bridge.

Use a two-core cable (2x0.75mm2, max. 2x2.5mm2), making sure its path is different from that 

of the mains power cables. The cable must not be longer than 50 m.

TECHNICAL CHARACTERISTICS AND DEFAULT SETTINGS

Time setting

12:00

Day setting

Day 1=Monday

Operation mode

Automatic

Manual mode heating temperature

20°C

Room antifreeze temperature

5°C

CU Compensation curve

0=Deactivated

OF Parallel curve offset

30°C

P1

Enable DHW programming

0=Deactivated

P2

Pre-Heating Function

0=Deactivated

P3

Max. number of daily time bands

6

P4

Heating min. temperature

-

P5

system 

fi

 lling

0=Deactivated

P6

Temperature unit of measure selection

0=°C

P7

Room temperature reading correction

0

P8

Telephone contact input operation selection

0=Switch off heating

P9

Manual temperature on closing of telephone contact input

20°C

Guaranteed average life of batteries

1 year

USER PARAMETER EDITING

Sliding Temperature - Compensation curve

By installing the external probe (optional), the control system can work with a Sliding Temperature. The external probe must be 

connected to the boiler card: refer to the relevant handbook for details. In this mode, the heating system temperature is adjusted 

according to the outside weather conditions in order to ensure high comfort and energy saving throughout the year. In particular, 

as the external temperature increases the system delivery temperature decreases according to a specific compensation curve. 

With the Sliding Temperature adjustment the temperature set through the "Heating temperature adjustment" setting becomes 

the maximum system delivery temperature. It is advisable to set a maximum value to allow system adjustment throughout its 

useful operating range. 

The compensation curve can be set from 1 to 10 according to the following graph.

20

30

40

50

60

70

80

90
85

20

10

0

-10

-20

1

2

3

4

5

6

8

9

10

7

Temperatura esterna

°C

Te

mperatura di mandat

a impianto

  

°C

1.  Keep the button   pressed for 3 seconds.

2.  The display shows the CU parameter.

 

Press the buttons 

 to modify the compensation 

curve by increments of 1 unit. By keeping the button pressed 

the value will change rapidly.

3.  Press any other button to exit the menu.

Set the compensation curve to 0 to disable Sliding Temperature adjustment.

The system must be adjusted at the time of installation by qualified personnel. Possible adjustments can in any case be made by 

the user to improve comfort. If the room temperature is lower than the required value, it is advisable to set a higher order curve 

and vice versa. Proceed by increasing or decreasing in steps of one and check the result in the room.

Sliding Temperature - Parallel curve offset

Once the Compensation curve has been set, parallel curve offset can be adjusted from 20 to 40 as shown in the following 

graphs:

20

30

40

50

60

70

80

90
85

20

10

0

-10

-20

1

2

3

4

5

6

8

9

10

7

Temperatura esterna

°C

Te

mperatura di mandat

a impianto

  

°C

20

10

0

-10

-20

20

30

40

50

60

70

80

90
85

1

2

3

4

5

6

8

9

10

7

Temperatura esterna

°C

Te

mperatura di mandat

a impianto

  

°C

1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button  . 

 

4. The display shows the OF parameter.

Press the buttons 

 to modify parallel curve offset in 1°C increments. By keeping the button pressed 

the value will change rapidly.

5. Press any other button to exit the menu.

Enable DHW programming

Follow the instructions given below to enable domestic hot water programming.
1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   twice. 

4. The display shows parameter P1.

Set to 0 using the buttons 

 to disable domestic hot water programming. Set to 1 using the buttons 

 to enable domestic hot water programming.

5. Press any other button to exit the menu.

To set the weekly automatic programme proceed as described in the section "Step 2. Automatic weekly programme setting", 

selecting the tap symbol at step "1" and setting EC (Economy) or CO (Comfort) at step "3" rather than a temperature value. In fact 

the remote control has a weekly time programmer based on two levels: during the COMFORT level, the boiler will maintain the set 

hot water tank temperature; during the ECO level, the boiler will not deliver domestic hot water. Refer to the boiler documentation 

for information on the type of hot water storage tank.

Important:

 Make sure the remote control is set to Winter mode with automatic operation.

Pre-Heating Function

This function is active only if the automatic heating mode has been selected.

When set to Automatic, the function anticipates the heating system start time (not before 00:00 hours on the same day) so that 

the room temperature set by the user is reached at the start of the programmed time band. The Remote Control calculates an 

initial hypothetical Pre-activation time: if the programmed room temperature is reached in a shorter time than that calculated, the 

Pre-Heating time will be decreased, and vice versa. This creates a self-learning process, for identifying the minimum necessary 

Pre-activation time.
The Remote Control also offers the possibility of setting a fixed Pre-Heating slope: In this case, the room temperature will be 

increased by 3°C an hour.

Therefore the automatic heating programme should be set according to the time when heat is required and not that when the 

heating system is to be started.

Follow the instructions given below to activate or deactivate this function.
1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   3 times.   

4. The display shows parameter P2.

 

Set to 0 using the buttons 

 to deactivate Pre-Heating. Set to 1 using the buttons 

 to 

activate Automatic Pre-Heating. Set to 2 using the buttons 

 to activate the Pre-Heating function 

with a 

fi

 xed slope of 3°C per hour.

5. Press any other button to exit the menu.

During the pre-heating function the room temperature °C symbol flashes.

The pre-heating function ends when the difference between the programmed room temperature and the actual room temperature 

is less than 0.5 °C.

Maximum number of daily time bands

The heating programme provides for 6 daily time bands for temperature levels, numbered from 1 to 6. If necessary, the time bands can 

be reduced to a minimum of two.
1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   4 times.    

4. The display shows parameter P3.

Use the buttons 

 to modify the number of daily time bands from 2 to 6. 

5. Press any other button to exit the menu.

Heating minimum temperature

Follow the instructions given below to set the minimum heating circuit water temperature in 1°C steps.

1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   5 times.   

4. The display shows parameter P4.

Use the buttons 

 to adjust the parameter in 1°C increments. By keeping the button pressed 

the value will change rapidly.

5. Press any other button to exit the menu.

System 

fi

 lling

This function manages the operation mode of the electric device for filling the water circuit in certain boiler models.
1. Keep the button   pressed for 3 seconds. 

2. The display shows the CU parameter.

3. Press the button   6 times.   

4. The display shows parameter P5.

Set to 0 using the buttons 

 to deactivate the electric 

fi

 lling device. Set to 1 using the buttons 

 to activate Manual system 

fi

 lling. Set to 2 using the buttons 

 to activate Automatic 

system 

fi

 lling.

5. Press any other button to exit the menu.

Important: 

Set the boiler control card to manual 

fi

 lling. In manual mode, if the sensor installed in the boiler 

detects insuf

fi

 cient pressure, the bar icon will 

fl

 ash on the display; press the RESET button to activate the 

special solenoid valve. During manual or automatic system 

fi

 lling the bar icon will become 

fi

 xed. Once the 

nominal pressure is restored, the remote control will return to the normal display.

A

B

A

B

External temperature °C

CH supply temper

ature °C

CH supply temper

ature °C

CH supply temper

ature °C

External temperature °C

External temperature °C