Follow the instructions given below to modify the preset automatic programme. 

1. Press 

the 

button  . If DHW programming is enabled, select the radiator symbol with the buttons 

 and con

fi

 rm 

with the button 

. The 6 daily time bands 

fl

 ash and number 1 of DAY 1 is shown in a box to indicate that time band 1 

of Monday can be modi

fi

 ed.

2.  Press the button  . The hours and minutes start 

fl

 ashing: use the buttons 

 to change the time band start time 

in 10 minute increments. By keeping the button pressed the hours and minutes will change rapidly.

3. Press 

the 

button  . The room temperature inside the house starts 

fl

 ashing: use the buttons 

 to change the 

temperature level in 0.1°C increments. By keeping the button pressed the temperature will change rapidly.

4.  Press the button  . The 6 daily time bands 

fl

 ash.

5.  Then press the button 

 to display time band 2 of Monday, modi

fi

 able by repeating steps 2 to 4.

6.  The remaining time bands can be displayed by selecting bands 3, 4, 5 or 6 with buttons 

 and repeating step 5.

7.  The programme setting for the following day can now be selected:
a.  Press the button 

 to display DAY 2. The Tuesday programme can be modi

fi

 ed by repeating steps 2 to 6.

b.  To copy the Monday programme to Tuesday, press the button 

. To copy the same programme also to the other days 

of the week, press the button 

 repeatedly.

Important!

 When setting the programme make sure each band has a different start time.

     

Personal programme note

     

Monday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time
Temperature level

Tuesday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time
Temperature level

Wednesday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time
Temperature level

Thursday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time
Temperature level

Friday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time
Temperature level

Saturday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time
Temperature level

Sunday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time
Temperature level

Step 5. Operation mode selection

OFF mode selection 

- If you are going away for prolonged period (also see Holiday Function) or if you simply want to switch off 

the heating, press the  button 

 and the symbol 

 is displayed. The heating is switched off, and switched on again 

only if the room temperature falls below 5°C: freezing protection function. If equipped with a hot water tank, the boiler will not 

deliver domestic hot water; instant-type hot water boilers will deliver hot water. 

Summer mode selection

 - To switch off the heating while maintaining the domestic hot water function, press the button 

 

and the symbol 

 is displayed. The heating is switched off, and switched on again only if the room temperature falls below 5°C: 

freezing protection function. Whatever the type of boiler, it will deliver hot water.

Winter mode selection

 - To reactivate heating and restore the previously set operation mode, press the button 

 again 

and the symbol 

 will appear on the display. Whatever the type of boiler, it will deliver hot water.

Heating automatic operation (in Winter mode)

 - Press the button 

 and the symbol 

 will appear 

on the display. The Remote Control will function according to the automatic weekly programme, displaying 

the 6 time bands: the time band active at that moment is displayed in a box. If the box is not shown, this 

means that the current time is between 00:00 hours and the start of time band 1.

Set temperature level exclusion - 

In automatic mode the room temperature value can be temporarily changed by pressing the 

buttons  

 in 0.1°C increments. By keeping the button pressed the temperature will change rapidly. The exclusion function, 

indicated on the display by the symbol 

 flashing, will be cancelled at the next time band change.

Heating manual operation (in Winter mode) - To use the Remote Control at a 

fi

 xed room temperature level, 

press the button 

 and the symbol   appears on the display (the 6 time bands are not displayed). 

Then set the room temperature value by pressing the buttons  

  in 0.1°C increments. By keeping the 

button pressed the temperature will change rapidly. Manual mode will be maintained until another operation 

mode is selected.

Step 6. Heating - DHW temperature adjustment

Heating

 - Press the button 

: the display shows the current heating circuit water temperature setting, adjustable using the 

buttons 

 in 1°C increments. Press any button to exit the menu.

 

DHW (domestic hot water)

 - Press the button 

: the display shows the current domestic hot water temperature setting, 

adjustable using the buttons 

 

 in 1°C increments.  Press any button to exit the menu.

SPECIAL FUNCTIONS

Holiday Function

The Holiday Function is used to switch off heating (also domestic hot water production for boilers with a storage tank) for a given 

period of time, from 1 hour to 45 days, adjustable in 1 hour increments. This makes it possible to save energy when away from 

home, whereas the previously set operation mode resumes as soon as the Holiday function ends. Heating is activated only if the 

room temperature falls below 5°C: freezing protection function.

Follow the instructions given below to activate and set the Holiday function.

1. Press 

the 

button 

 

. The symbol 

 starts 

fl

 ashing and the hours and minutes become -00:01, which is the time 

remaining before the end of the Holiday function. 

2. Use 

the 

buttons 

 to extend the time remaining until the end of the Holiday function in 1 hour increments (-00:01 

means 1 hour; -45:00 means 45 days). By keeping the button pressed the time and days will change rapidly.

3.  During the Holiday function the display will continue to show the time remaining until the end of the function.

To cancel the Holiday function press the button 

 or any other button associated with a different operation 

mode.

1

  OFF, summer-winter mode/reset faults selection 

button

2

  Automatic/manual heating mode button

3

  Heating - DHW programming button

4

  Time and day setting button

5

  Heating temperature adjustment button

6

  DHW temperature adjustment button

7

  User information/settings button

8

  Holiday function button/copy heating - DHW programme 

day

9

  Manual room temperature decrease button

10

  Manual room temperature increase button

11

  Heating programme time bands

12

  Day of week

13

  Hours and minutes

14

 OFF mode

15

  Heating manual mode

16

  Heating automatic mode

17

 Holiday function

18

  Burner on and current power level

19

 Summer mode

20

 DHW mode

21

 Winter mode 

22

 Heating mode

23

 Fault

24

 Room temperature 

25

 Room antifreeze

26

  External temperature (only with optional external probe 

connected)

27

 Batteries 

fl

 at

28

  Flashing: Finding synch.

 

Fixed: RF communication ok

OVERVIEW OF RF REMOTE CONTROL

1

2

3

10

9

8

4

5

6

7

14 15 16

17

11

19 12 13

18

21

25

23

22

26

24

20

27 28

OVERVIEW OF RF BRIDGE

3

1

2

1

 - Left LED

2

 - TEST mode button

3

 - Right LED

CONFIGURE AND ACTIVATE THE REMOTE CONTROL IN 6 EASY STEPS

Step 1. Installation check (RF BRIDGE)

Make sure the RF bridge is electrically fed through the connection with the boiler card. The left LED must activate 3 fast blinks 

every 2 seconds.

Step 2. Battery installation (RF REMOTE CONTROL)

Note:

 Follow the instructions in only if installing the RF Remote Control for the 

fi

 rst time

or if the RF Remote Control display activates the symbol 

 or if the display is off (no symbols or numbers appear). 

Otherwise go straight to Step 3: 

Correct setting of time and day

.

To install the batteries:

1.  Remove the front cover by prising with a screwdriver at points A and B as shown in the 

fi

 gure, to access the batteries.

A

B

2.  Insert the two 1.5V AA LR6 alkaline batteries supplied with the RF Remote Control, making sure to 

fi

 t them in the right 

direction (indicated inside the front part).

3. Re

fi

 t the front part of the RF Remote Control. (Make sure to centre the front part on the rear part to ensure correct insertion 

of the contacts).

4. Wait: 

fi

 nding synchronism between RF Remote Control and RF Bridge. The operation ends when the symbol (

) shown on 

the RF Remote Control display stops 

fl

 ashing. Otherwise remove the batteries from the RF Remote Control and repeat Steps 

1 and 2: if necessary, bring the RF Remote Control nearer the RF Bridge to obtain more reliable RF communication.

Step 3. Setting the time and day

1.  Press the button 

. The day starts 

fl

 ashing: use the 

 buttons to set the correct day of the week, where DAY 

1 is Monday and DAY 7 is Sunday.

2.  Press the button 

. The hours start 

fl

 ashing: use the 

 buttons to set the correct hours from 00 to 23.

3.  Press the button 

. The minutes starts 

fl

 ashing: use the buttons 

 to set the correct minutes from 00 to 

59.

4.  Press the button 

.

Step 4. Setting the automatic weekly programme

Once the time and day have been set, the Remote Control will follow the preset automatic programme. The heating programme 

provides for 6 daily time bands for temperature levels, numbered from 1 to 6. The time bands can be set between 00:00 and 

24:00 in 10 minute increments. Each temperature level can be set between 7°C and 32.5°C in 0.1°C increments. Therefore any 

combination of time and temperature during the day can be programmed, and different for each day of the week. The preset 
automatic programme is:

From Monday to Friday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time

06:30

08:00

12:00

14:00

18:00

22:30

Temperature level

21°C

18°C

21°C

18°C

21°C

16°C

From Saturday to Sunday

Band 1

Band 2

Band 3

Band 4

Band 5

Band 6

Start time

08:00

10:00

12:00

14:00

18:00

22:30

Temperature level

21°C

21°C

21°C

21°C

21°C

16°C