ACCESSORIES AND OPTIONAL EQUIPMENT
"
Storing and hydronic kit
" options
Storing and hydronic kit
MKT SS
Pipe kit without tank
This accessory consists of steel pipes insulated with thermal barrier material and allows
the water inlet/outlet connection to be routed outside the unit.
M1P SS 2P STD
1 Standard pump
Allows the circulation of the water on the plant side.
M1P SS 2P HP1
1 High head pump
Allows the circulation of the water on the plant side and guarantees a higher available
static head, suitable for high pressure drop plants.
M1PM SS 2P STD
1 Standard modulating pump
Allows the circulation of the water on the plant side with the possibility to set the rota-
tional speed of the pump in order to get the requested flow rate without the necessity to
install other setting devices.
M1PM SS 2P HP1
1 Standard modulating high head pump
Allows the circulation of the water on the plant side, ensuring a higher available static
head, suitable for high pressure drop plants, with the possibility to set the rotational
speed of the pump in order to get the requested flow rate without the necessity to install
other setting devices.
M2P SS 2P STD
2 Standard pumps
Allows the circulation of the water on the plant side and includes a second pump instal-
led as a backup to the first.
M2P SS 2P HP1
2 High head pumps
Allows the circulation of the water on the plant side, ensuring a higher available static
head, suitable for high pressure drop plants, and includes a second pump installed as
a backup to the first.
MKT AM
Pipe kit with tank
This accessory consists of steel pipes insulated with thermal barrier material and allows
the water inlet/outlet connection to be routed outside the unit.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M1P AM 2P STD
Tank and 1 standard pump
Allows the circulation of the water on the plant side.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M1P AM 2P HP1
Tank and 1 high head pump
Allows the circulation of the water on the plant side and guarantees a higher available
static head, suitable for high pressure drop plants.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M1PM AM 2P STD
Tank and 1 modulating standard pump
Allows the circulation of the water on the plant side with the possibility to set the rota-
tional speed of the pump in order to get the requested flow rate without the necessity to
install other setting devices.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M1PM AM 2P HP1
Tank and 1 modulating high head pump
Allows the circulation of the water on the plant side, ensuring a higher available static
head, suitable for high pressure drop plants, with the possibility to set the rotational
speed of the pump in order to get the requested flow rate without the necessity to install
other setting devices.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M2P AM 2P STD
Tank and 2 standard pumps
Allows the circulation of the water on the plant side and includes a second pump instal-
led as a backup to the first.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M2P AM 2P HP1
Tank and 2 high head pumps
Allows the circulation of the water on the plant side, ensuring a higher available static
head, suitable for high pressure drop plants, and includes a second pump installed as
a backup to the first.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M1P PS 2P STD
Tank and 1 standard pump
(primary and secondary configuration)
Allows the circulation of the water on the primary between the tank and the heat ex-
changer.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.
M2P PS 2P STD
Tank and 2 standard pumps
(primary and secondary configuration)
Allows the circulation of the water on the primary between the tank and the heat ex-
changer and includes a second pump installed as a backup to the first.
The thermal inertia of the buffer tank allows to reduce the number of compressor starts
and to guarantee a more stable flow temperature.