Cleaning the boiler and flue
To clean the boiler properly (fig. 21):
•
Close the gas cock ahead of the unit and disconnect the power supply.
•
Remove the front panel of the boiler.
•
Lift the casing cover by pressing upwards.
•
Remove the insulation placed over the anti-backflow device.
•
Remove the fume chamber closing plate.
•
Remove the burner assembly (see next section).
•
Clean from the top downwards, using a flue brush.
•
Clean the fume exhaust ducts between the cast iron elements of the boiler shell with a vacuum cleaner.
•
Carefully refit all the previously removed parts and check the tightness of the gas circuit and combustion ducts.
•
During cleaning operations take care not to damage the fume thermostat bulb at the back of the fume chamber.
fig. 21 - Boiler cleaning