51
EN
Cod. 3542B250 - Rev. 00 - 02/2022
OMNIA S HYBRID C 3.2
9.1.2 Boiler service menu
ACCESS TO THE SERVICE MENU AND CHANGING PARAMETERS CAN ONLY BE CARRIED OUT BY QUALIFIED
PERSONNEL.
To continue, you must enter the password “1234”. Set the cell value with the SW6 and SW7 buttons while you can change positions with the SW1 and SW2 buttons.
Confirm with the button.
Menu for modifying the [TSP] parameters
You can scroll the list by pressing the SW1 and SW2 buttons while the value is displayed with the button. To modify, press the SW6 and SW7 buttons, confirm
with the button or cancel with the button.
Index Description
Modulation
Default
b01 Boiler type selection
3 = COMBINED MONOTHERMAL (DO NOT MODIFY)
3
b02 Boiler type
1 = 24_C
2 = 28_C
3 = 34_C
4 = 45_C
5 = 24_C (high range)
6 = 28_C (high range)
7 = 34_C (high range)
6
b03 Gas type
0 = Methane
1 = LPG
2 = Propane-air
0
b04 Water system pressure protection selection 0 = Pressure switch
1 = Pressure transducer
1
b05 Summer/Winter function
0 = WINTER - SUMMER - OFF
1 = WINTER - OFF
0 = Enabled
b06 Variable input contact function selection
0 = Flow meter exclusion
1 = System thermostat
2 = Second Room thermostat
3 = Warning/Notification
4 = Thermostat safety device
2
b07 LC32 relay board operation selection
0 = External gas valve
1 = Alarm
2 = System loading solenoid valve
3 = Solar 3-way valve
4 = Second heating pump
5 = Alarm2
6 = Burner on
7 = Antifreeze active
0
b08 Hours without DHW
withdrawal
0-24 hours (time for temporary deactivation
of comfort without withdrawal)
24
b09 Fault 20 status selection
0 = Disabled
1 = Enabled (Only for versions with pressure transducer)
0
b10 Not implemented
--
--
b11
Flow meter timing
0 = Disabled
1-10 = seconds
0
b12 Comfort mode
0 = Activation with withdrawal
1 = Always active
0
b13 Not implemented
--
--
b14 DHW factor
0 - 1
0
b15 Flow meter type selection
1 = Flow. (450 sys/l)
2 = Flow. (700 sys/l)
3 = Flow (190 sys/l)
3
b16 Not implemented
--
--
b17 Not implemented
--
--
b18 DHW mode activation flow
rate
0-100L/min/10
25
b19 DHW deactivation flow
rate
0-100L/min/10
20
b20 Flue material selection
0 = Standard
1 = PVC
2 = CPVC
0
b21 Not implemented
--
--
b22 Not implemented
--
--
b23 Maximum temperature standard flue switch
off
60-110°C
105
b24 Maximum temperature PVC flue switch off 60-110°C
93
b25 Maximum temperature CPVC flue switch off 60-110°C
98
b26 Not implemented
--
--
Summary of Contents for OMNIA S HYBRID C 3.2
Page 86: ... ...
Page 87: ... ...
Page 88: ...FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli com Made in Italy ...