95
EN
Cod. 3541T090 - Rev. 00 - 06/2019
MAINTENANCE
Boiler - Exchanger insulation replacement
fig. 188 -
• Disconnect the power supply and close the gas tap upstream of the valve.
• Remove the cover of the heat exchanger and the burner (see fig. 188).
• Pull out the electrode “1”.
• Rotate the insulating disc “2” and remove it.
Boiler - Fan
fig. 189 -
• Disconnect the power supply and turn off the gas cock ahead of the valve.
• Remove the connector from the fan
• Remove the clamp “1” and undo the screws “2”.
• Remove the fan electrical connections and then the fan.