15
1
2
3
4
5
1 and 2.5
>3 and
≤
6
>6 and
≤
10
>10 and
≤
16
>16 and
≤
25
>25 and
≤
32
>32 and
≤
50
>50 and
≤
63
≤
3
0.75 and 1
1 and 1.5
1.5 and 2.5
2.5 and 4
4 and 6
6 and 10
10 and 16
1 and 2.5
1 and 2.5
1.5 and 4
2.5 and 6
4 and 10
6 and 16
10 and 25
0.5 and 0.75
Rated current of appliance
(
A
)
Nominal cross-sectional area (mm
2
)
Flexible cords
Cable for fixed wiring
Table 5-3
Please refer to the corresponding wired controller manual for the wired
controller wiring.
Power
supply
Communication wire between
IDU and wired controller *
220-240V~50/60Hz
Shielded
×AWG16-AWG18
CIRCUIT BREAKER/FUSE (A)
15/15
Phase
Volt and frequency
1-phase
Refer to Table 5-2 and Table 5-3 for the specifications of the power cord and communication wire. A wiring capacity that is too small will cause
the electrical wiring to become too hot, and result in accidents when the unit burns and becomes damaged.
Table 5-2
Model
ALL
Select the wire diameters (minimum value) individually for each unit based on Table 5-3.
The maximum allowable voltage range variation between phases is 2%.
Select the circuit breaker that has a contact separation of no less than 3 mm in all poles to provide full disconnection.MFA is used to select the
current circuit breakers and residual current operation breakers:
AC FAN
Figure 5-22 Wiring diagram (version 3V-VM; 3V-VN)
The grounding wire in the electrical control box needs to be longer than the current-carrying wire.