DOMIcondens F 28

700

400

196

85

115

200

330

INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

Summary of Contents for DOMIcondens F 28

Page 1: ...Supplied By www heating spares co Tel 0161 620 6677 3540S920 cod 3540S920 05 2009 Rev 00 DOMIcondens F 28 700 400 196 85 115 200 330 INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Page 2: ...r supply During the first 5 seconds the display shows the card software version Open the gas cock ahead of the boiler The boiler is now ready to operate automatically whenever hot water is drawn or in case of a room thermostat demand Boiler lighting and shutdown Press the on off button detail 7 fig 1 for 5 seconds fig 2 Turning the boiler off When the boiler is turned off the PCB is still powered ...

Page 3: ...ding those with sealed chamber The unit is suitable for operation in a partially protected place in conformity with EN 297 A6 with minimum temperature 5 C If equipped with the special antifreeze kit it can be used with minimum temperatures to 15 C The boiler must be installed is a protected place e g under the slope of a roof inside a balcony or in a sheltered recess The place of installation must...

Page 4: ...t product in the right concentration accord ing to the producer s instructions 3 4 Gas connection The gas must be connected to the relevant connection see fig 7 in conformity with cur rent standards with a rigid metal pipe or with a continuous surface flexible s steel tube installing a gas cock between the system and boiler Make sure all the gas connections are tight 3 5 Electrical connections B T...

Page 5: ...etely establish the layout of the system of split flues including accessories and outlet terminals 2 Consult the table 4 and identify the losses in meq equivalent metres of every com ponent according to the installation position 3 Check that the sum total of losses is less than or equal to the maximum permissible length in table 3 Table 3 Baffles for separate ducts Table 4 Accessories 3 7 Condensa...

Page 6: ...djust the maximum pressure by turning the screw G clockwise to increase the pressure and anticlockwise to decrease it Disconnect one of the two fastons C from the modureg F on the gas valve Adjust the minimum pressure by turning the screw E clockwise to increase the pressure and anticlockwise to decrease it Turn the burner on and off checking that the minimum pressure remains stable Reconnect the ...

Page 7: ...aults marked with the letter F cause temporary shutdowns that are automatically reset as soon as the value returns within the boiler s normal working range Table of faults Table 5 Fault list Fault code Fault Possible cause Cure A01 No burner ignition Excessive condensate level Empty clean the trap No gas Check the regular gas flow to the boiler and that the air has been eliminated from the pipes I...

Page 8: ...500 2 000 Q l h H m H 2 O A 3 2 1 Data Unit DOMIcondens F 28 Max heating capacity kW 27 2 Q Min heating capacity kW 10 0 Q Max Heat Output in heating 80 60 C kW 26 2 P Min Heat Output in heating 80 60 C kW 9 2 P Max Heat Output in heating 50 30 C kW 28 2 Min Heat Output in heating 50 30 C kW 9 6 Max heating capacity in hot water production kW 27 2 Min heating capacity in hot water production kW 10...

Page 9: ...ndens F 28 9 EN cod 3540S920 05 2009 Rev 00 fig 21 Wiring diagram X4 1 2 3 4 5 6 7 43 278 11 10 9 8 7 6 5 4 3 2 1 X6 114 42 47 38 L N X1 X5 1 X3 3 2 X7 32 4 3 2 1 44 DBM02 1B 81 230V 50 Hz T T T 16 ON DAY 22 0004 REMOVE TO CONNECT THE CLOCK 139 193 126 1 2 72 ...

Page 10: ...SCALE REDUCER HAS BEEN FITTED FOR THE DOMESTIC HOT WATER MODE MEASURE RECORD GAS RATE ft3 hr MAXIMUM BURNER OPERATING PRESSURE IF APPLICABLE mbar COLD WATER INLET TEMPERATURE C HOT WATER OUTLET TEMPERATURE C WATER FLOW RATE lts min FOR CONDENSING BOILERS ONLY CONFIRM THE FOLLOWING THE CONDENSATE DRAIN HAS BEEN INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS YES FOR ALL INSTALLATIONS C...

Page 11: ...GI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 3 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 5 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 6 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SI...

Page 12: ... the event of a boiler shut down check this is not caused by lack of electricity supply gas supply or low water pressure before calling our Customer Service Helpline Lichfield Road Branston Industrial Estate Burton Upon Trent Staffordshire DE14 3HD Tel 08707 282 885 Fax 08707 282 886 Should you require any assistance during the installation call our Technical Service Helpline on 08707 282 885 opti...