Ferroli DIVAtech F37 D Instructions For Use, Installation And Maintenance Download Page 4

DIVAtech F37 D

4

EN

cod. 3541H480  -  Rev. 00 - 09/2015

3. INSTALLATION
3.1 General Instructions

BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSON-
NEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL
MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRESCRIPTIONS OF NA-
TIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP.

3.2 Place of installation

The combustion circuit is sealed with respect to the place of installation, therefore the
unit can be installed in any room. However, the place of installation must be sufficiently
ventilated to prevent the creation of dangerous conditions in case of even small gas
leaks. This safety standard is required by the EEC Directive no. 2009/142 for all gas
units, including those with sealed chamber
The unit is suitable for operation in a partially protected place in compliance with EN 297
pr A6, for temperatures to -5°C. It is advisable to install the boiler under the slope of a
roof, inside a balcony or in a sheltered recess.
Therefore the place of installation must be free of dust, flammable materials or objects
or corrosive gases.
The boiler is arranged for wall mounting and comes standard with a hooking bracket. Fix
the bracket to the wall according to the measurements given in the cover drawing and hook
the boiler on it. A metal template for marking the drilling points on the wall is available by
request. The wall fixing must ensure stable and effective support for the generator.

A

If the unit is enclosed in a cabinet or mounted alongside, a space must be pro-
vided for removing the casing and for normal maintenance operations

3.3 Plumbing connections
Important

B

The safety valve outlet must be connected to a funnel or collection pipe to pre-
vent water spurting onto the floor in case of overpressure in the heating circuit.
Otherwise, if the discharge valve cuts in and floods the room, the boiler manu-
facturer cannot be held liable.

B

Before making the connection, check that the unit is arranged for operation with
the type of fuel available and carefully clean all the system pipes.

Carry out the relevant connections according to the cover diagram and the symbols giv-
en on the unit.

Note:

 The unit has an internal bypass in the heating circuit.

Water system characteristics

In the presence of water harder than 25° Fr (1°F = 10ppm CaCO

3

), use suitably treated

water in order to avoid possible scaling in the boiler.

Antifreeze system, antifreeze fluids, additives and inhibitors

When necessary, antifreeze fluids, additives and inhibitors can be used only if the man-
ufacturer of such fluids or additives guarantees that they are suitable and do not cause
damage to the exchanger or other components and/or materials of the boiler and system.
Do not use generic antifreeze fluids, additives or inhibitors that are not specific for use in
heating systems and compatible with the materials of the boiler and system.

3.4 Gas connection

The gas must be connected to the relevant union (see figure on cover) in conformity with
the current regulations, with a rigid metal pipe or with a continuous surface flexible s/steel
tube, installing a gas cock between the system and boiler. Make sure all the gas connec-
tions are tight.

3.5 Electrical connections
Important

B

The unit must be connected to an efficient earthing system in conformity with
current safety regulations. Have the efficiency and suitability of the earthing
system checked by professionally qualified personnel; the Manufacturer de-
clines any liability for damage caused by failure to earth the system.
The boiler is prewired and provided with a "Y" type cable (without plug) for con-
nection to the electric line. The connections to the power supply must be per-
manent and equipped with a double-pole switch with contact opening distance
of at least 3 mm, installing fuses of max. 3A between the boiler and the line.
Make sure to respect the polarities (LINE: brown wire / NEUTRAL: blue wire /
EARTH: yellow/green wire) in connections to the electric line.

B

The unit's power cable must not be replaced by the user; if damaged, switch
the unit off and have the cable replaced by professionally qualified personnel.
If replacing the power cable, only use 

"HAR H05 VV-F"

 3x0.75 mm2 cable with

max. ext. diameter of 8 mm.

Room thermostat (optional)

B

IMPORTANT: THE ROOM THERMOSTAT MUST HAVE VOLTAGE-FREE
CONTACTS. CONNECTING 230 V TO THE ROOM THERMOSTAT TERMI-
NALS WILL PERMANENTLY DAMAGE THE ELECTRONIC BOARD.
When connecting time controls or a timer, do not take the power supply for
these devices from their breaking contacts Their power supply must be by
means of direct connection from the mains or with batteries, depending on the
kind of device.

Accessing the electrical terminal block

The electrical terminal block can be accessed after removing the casing. The layout of
the terminals for the various connections is also given in the wiring diagram in fig. 21.

fig. 8 - Accessing the terminal block

3.6 Fume ducts
Important

The unit is a "C type" with sealed chamber and forced draught, the air inlet and fume out-
let must be connected to one of the following extraction/suction systems. The unit is ap-
proved for operation with all the 

Cny

 flue configurations given on the dataplate. Some

configurations may be expressly limited or not permitted by law, standards or local reg-
ulations. Before installation, check and carefully follow the instructions. Also, comply with
the instructions on the positioning of wall and/or roof terminals and the minimum distanc-
es from windows, walls, ventilation openings, etc.

Baffles

Boiler operation requires fitting the baffles supplied with the unit. Make sure the boiler
has the correct baffle (when used) and that it is properly positioned .

A

 Baffle replacement with 

boiler not installed

B

 Baffle replacement with 

boiler and fume ducts already installed

1

2 3 4

5 6

72

139

138

3

4

A

1

2

B

3

2

1

4

5

6

Summary of Contents for DIVAtech F37 D

Page 1: ... cod 3541H480 Rev 00 09 2015 DIVAtech F37 D F A 85 76 54 51 81 104 B C D E 175 127 330 700 450 330 196 110 115 115 110 A B C D E F EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Page 2: ...ection button 8 DHW symbol 9 DHW mode 10 Summer mode 11 Multifunction 12 Eco Economy mode 13 Heating 14 Heating symbol 15 Burner lit and actual power level flashing during combustion fault function 16 Service Tool connection 17 Water gauge Indication during operation Heating A heating demand generated by the Room Thermostat or Remote Timer Control is in dicated by flashing of the hot air above the...

Page 3: ... fig 1 for 5 seconds to access the Sliding temperature menu the display shows CU flashing Use the DHW buttons detail 1 fig 1 to adjust the curve from 1 to 10 according to the characteristic By setting the curve to 0 sliding temperature adjustment is disabled Press the heating buttons detail 3 fig 1 to access parallel curve offset the display shows OF flashing Use the DHW buttons detail 1 fig 1 to ...

Page 4: ...ing systems and compatible with the materials of the boiler and system 3 4 Gas connection The gas must be connected to the relevant union see figure on cover in conformity with the current regulations with a rigid metal pipe or with a continuous surface flexible s steel tube installing a gas cock between the system and boiler Make sure all the gas connec tions are tight 3 5 Electrical connections ...

Page 5: ...ergo similar wind conditions within 50 cm C3X Roof vertical exhaust and intake Inlet outlet terminals like for C12 C5X Wall or roof exhaust and intake separate or in any case in areas with different pressures The exhaust and intake must not be positioned on opposite walls C6X Intake and exhaust with separately certified pipes EN 1856 1 B2X Intake from installation room and wall or roof exhaust IMP...

Page 6: ...T mode press the heating buttons details 3 and 4 fig 1 for 5 seconds The TEST mode is automatically disabled in any case after 15 minutes or on stopping of hot water drawing if enough hot water is drawn to activate the DHW mode Pressure adjustment at the burner Since this unit has flame modulation there are two fixed pressure settings minimum and maximum which must be those given in the technical ...

Page 7: ... Code fault Fault Possible cause Cure A01 No burner ignition No gas Check the regular gas flow to the boiler and that the air has been eliminated from the pipes Ignition detection electrode fault Check the wiring of the electrode and that it is correctly positioned and free of any deposits Faulty gas valve Check the gas valve and replace it if necessary Gas valve wiring disconnected Check the wiri...

Page 8: ...4 System filling cock 14 Safety valve 81 Ignition and detection electrode 16 Fan 95 Diverter valve 19 Combustion chamber 114 Water pressure switch 22 Burner 138 External probe not supplied 27 Copper exchanger for heating and hot water 139 Room unit not supplied 28 Fume manifold 187 Fume baffle 29 Fume outlet manifold 194 DHW exchanger 32 Heating circulating pump 241 Automatic bypass 36 Automatic a...

Page 9: ... h 1 48 Burner nozzles G31 n x Ø 17 x 0 79 Gas supply pressure G31 mbar 37 Max gas pressure at burner G31 mbar 35 0 Min gas pressure at burner G31 mbar 5 0 Max gas delivery G31 kg h 3 10 Min gas delivery G31 kg h 1 10 Max working pressure in heating bar 3 PMS Min working pressure in heating bar 0 8 Max heating temperature C 90 tmax Heating water content litri 1 5 Heating expansion tank capacity li...

Page 10: ...iring diagram fig 21 Electrical circuit A Important Before connecting the room thermostat or the remote timer control remove the jumper on the terminal block 81 1kW L N 230V 50 Hz 16 N L 32 L N T T 278 T 42 4 3 2 1 44 38 114 ABM01 LC32 3 2 1 95 72 139 138 ...

Page 11: ...er FERROLI S p A Address Via Ritonda 78 a 37047 San Bonifacio VR Italy declares that this unit complies with the following EU directives Gas Appliance Directive 2009 142 Efficiency Directive 92 42 Low Voltage Directive Electromagnetic Compatibility Directive EN ...

Page 12: ...FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli it ...