1.6 OVERALL DIMENSIONS
fig. 1 -
MOD.
9
12
18
24
UM
W
700
800
845
mm
W1
73
70
69
mm
H
550
554
702
mm
D
275
333
363
mm
1.7 APPLICATION FIELD
We recommend to use of the unit under the conditions described below.
Operating mode Parameter
Inner side
Outer side
U.M
B.S
B.U
B.S
B.U
Cooling
Maximum inlet air temperature
32
23
50
\
(°C)
Minimum inlet air temperature
17
16
-15
\
(°C)
Heating
Maximum inlet air temperature
30
\
30
25
(°C)
Minimum inlet air temperature
0
\
-15
-13
(°C)
All
Supply Voltage
230±10%
(V)
Supply Frequency
50±2
(Hz)