BLUEHELIX PRO C
EN
5. TECHNICAL DATA AND CHARACTERISTICS
fig. 26 - General view
Table. 9 - Legend - figures cap. 5
fig. 27 - Hydraulic circuit
F39
External probe fault
Probe damaged or wiring
shorted
Check the wiring or replace the sen-
sor
Probe disconnected after
activating the sliding
temperature
Reconnect the external probe or dis-
able the sliding temperature
A41
Sensor positioning
Heating sensor detached
from pipe
Check the correct positioning and
operation of the heating sensor
A42
Heating sensor fault
Sensor damaged
Replace the sensor
F43
Exchanger protection
activation
No system H
2
O circula-
tion
Check the circulating pump
Air in the system
Vent the system
A44
Sensor positioning
DHW sensor detached
from pipe
Check the correct positioning and
operation of the DHW sensor
F52
Heating sensor fault
Sensor damaged
Replace the sensor
A61
Controller fault
ABM03
$
Controller internal error
ABM03
$
Check the earth connection and
replace the controller if necessary.
A62
No communication
between controller and
gas valve
Controller not connected
Connect the controller to the gas
valve
Valve damaged
Replace the valve
A63
F64
A65
F66
Controller fault
ABM03
$
Controller internal error
ABM03
$
Check the earth connection and
replace the controller if necessary.
A23
A24
F20
F21
A26
F40
F47
Card parameter fault
Wrong card parameter
setting
Check the card parameter and mod-
ify it if necessary.
Fault code
Fault
Possible cause
Cure
32
114
14
36
186
56
191
196
350
81
42
221
278
10
8
7
9
11
44
39
136
37
193
35
74
7
Gas inlet
104
Fuse
8
Domestic hot water outlet
114
Water pressure switch
9
Cold water inlet
136
Flow meter
10
System delivery
138
External probe (optional)
11
System return
139
Remote timer control (optional)
14
Pressure relief valve
154
Condensate drain pipe
16
Fan
186
Return sensor
32
Heating circulating pump
191
Fume temperature sensor
35
Air separator
193
Trap
36
Automatic air vent
196
Condensate tray
37
Cold water inlet filter
221
Bypass cock
39
Flow regulator
256
Modulating heating circulating pump signal
42
DHW temperature sensor
278
Double sensor ( Heating)
44
Gas valve
340
Bypass pipe
56
Expansion tank
350
Fan/Burner assembly
72
Room thermostat (not supplied)
A
ON/OFF switch (configurable)
74
System filling cock
81
Ionisation/ignition electrode
8
221
10
9
14
114
37
56
36
32
136
39
74
42
340
193
154
186
278
35
11
cod. 3541F553 - Rev. 00 - 04/2017
Summary of Contents for BLUEHELIX PRO 25C
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ... 552 6 S 9LD 5LWRQGD D 6DQ RQLIDFLR 9HURQD 7 ZZZ IHUUROL FRP ...