Ferroli 20-V Installation And Operation Manual Download Page 5

5

GENERAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

OVERALL DIMENSIONS

18

°C

A

C

B

Mod.

UM

20-V

30-V

40-V

A

mm

790

1030

1030

B

mm

270

310

310

C

mm

190

205

205

NOTES:
(1) 

Operation in the Heating mode. The data refer to:

Inlet Water temperature: 

70°C , 

Δ

t water 10°C

- Ambient Air temperature 

20°C D.B.

(2) 

Operation in Heating mode. The data refer to:

- Inlet Water temperature 

50°C,  

Δ

t water 5°C

- Ambient Air temperature 

20°C D.B.

(3) 

Operation in the Cooling mode. The data refer to:

Inlet Water temperature: 

7°C , 

Δ

t water 5°C

- Ambient Air temperature 

27°C D.B., 19°C W.B.

(4) 

Sound pressure in a 100 m

3

room with 0.5 sec. reverberation time. 

(NOTE):

the water pressure drops on the wet side are inclusive of los-

ses from the valve.

MOD.

UM

20

30

40

Heating capacity 

(1)

max.

[W]

3400

4500

6600

med.

[W]

2900

3800

5500

min

[W]

2550

3300

4800

Water flow rate

(1)

[l/h]

292

387

568

Water pressure drop on wet side

(1)

[Kpa]

14,0

17,0

24,0

Heating capacity 

(2)

max.

[W]

2500

3400

5000

Water pressure drop on wet side

(2)

[Kpa]

14,0

18,0

31,0

Cooling capacity 

(3)

max.

[W]

1800

2700

3700

med.

[W]

1400

2250

3100

min

[W]

1200

2000

2700

Water flow rate 

(3)

[l/h]

310

464

636

Dehumidification at max speed

(3)

[g/h]

400

850

1110

Sensible cooling capacity at max speed 

(3)

[W]

1530

2100

2960

Water pressure drop on wet side 

(3)

[Kpa]

17

21

37

Air flow rate

max.

[m³/h]

380

500

730

med.

[m³/h]

260

410

600

min

[m³/h]

200

350

520

N° fans

1

1

1

Sound pressure 

(4)

max.

[dB(A)]

41

42

47

med.

[dB(A)]

35

40

45

min

[dB(A)]

32

37

43

Power input

[W]

30

36

46

Wet connections

F

[ " ]

1/2" F

1/2" F

1/2" F

Condensation drain pipe diameter

F

[mm]

16

16

16

three-way valve connection

Type

-

electronic  ON-OFF 

Ø

[ " ]

1/2"

1/2"

1/2"

Packaging dimension

L

mm

865

1100

H

mm

285

290

D

mm

340

380

Net weight indoor unit

kg

8

14

Gross weight indoor unit

kg

10

15

Summary of Contents for 20-V

Page 1: ...INSTALLATION AND OPERATION MANUAL GB FCP 20 V 30 V 40 V Wall mounted Fan coil 18 C...

Page 2: ...the appliance complies with the European Machine Directive governing safety matters The quality level is constantly supervised thus FERROLI products stand for Safety Quality and Reliability Ask the De...

Page 3: ...UNIT 7 ELECTRICAL CONNECTIONS 7 WIRING DIAGRAMS 8 INSTALLATION OF THE UNIT 8 OTHER POSITIONS FOR INSTALLATION 10 WET CONNECTIONS 11 CONDENSATION DRAINAGE 11 AIR VENT 12 SETTING AT WORK 13 USE OF THE...

Page 4: ...he haulage contractor of its entity and inform our customer management office Only in this way will you be able to receive the missing mate rials or reimbursement of damages in the fastest possible wa...

Page 5: ...med W 2900 3800 5500 min W 2550 3300 4800 Water flow rate 1 l h 292 387 568 Water pressure drop on wet side 1 Kpa 14 0 17 0 24 0 Heating capacity 2 max W 2500 3400 5000 Water pressure drop on wet sid...

Page 6: ...es Carefully read the stickers on the machine Never cover them Replace them immediately should they be damaged Do not use the machine in an explosive atmosphere The power line must be regularly ground...

Page 7: ...e top side of the box 3 Take hold of the unit and lift it fully out of the box 4 Remove the side protections and take off the nylon wrapping UNITS OPENING 1 Remove the screws and take off the front pa...

Page 8: ...act positions of the expansion plugs and the hole that passes through the wall MACHINE INSTALLATION Models 30 V 40 V WIRING DIAGRAMS To allow the conditioner to operate the electrical connections must...

Page 9: ...OTHER POSITIONS FOR INSTALLATION section 5 Make a 70 mm hole in the wall Fig 2 slightly slanting towards the outside Now begin to drill on one side of the walll A and terminate from the opposite side...

Page 10: ...y to the required direction 3 Make the cooling pipe connections between the pipes of the interior unit and those of the exterior unit MACHINE INSTALLATION 7 Raise and carefully turn the pipe sections...

Page 11: ...eals Model Couplings 20 V 1 2 30 V 40 V MACHINE INSTALLATION CONDENSATION DRAINAGE The following procedure makes sure that any condensation that forms flows correctly out of the machine 1 Connect the...

Page 12: ...e that the valve opens This allows water to start entering the coils 2 Check to make sure that there are no leaks from the wet connections If there are no leaks open the air vent will now start to lea...

Page 13: ...e settings made via the unit s remote control 5 TEMP TIME Keys for selecting the TEMPERATU RE TIME Allow the user to select the ambient temperature in the room and the timer clock increases the settin...

Page 14: ...d more rapidly than the normal operating mode SLEEP mode press the SLEEP key to preset the machine for the overnight mode shown by the relative symbol on the display 1 nin the Cooling mode COOL the te...

Page 15: ...time setting SETTING AT WORK EMERGENCY KEY OF THE UNIT The ON OFF emergency key is situated on the front of the unit It allows the unit to be powered and or switched off if the remote con trol is fau...

Page 16: ...er with activated carbon 1 Remove the plug from the power socket 2 Raise the front panel 3 Remove the intake grille by pulling it outwards 4 Slip it out of its guide 5 Only clean with a blast of air D...

Page 17: ...The manufacturer declines all liability for inaccuracies in this manual when due to printing or typing errors...

Page 18: ...Ferroli spa 37047 San Bonifacio Verona Italy Via Ritonda 78 A tel 39 045 6139411 fax 39 045 6100933 www ferroli it Code 3QE24542...

Reviews: