06. Technical specifications

DANTE I/O

∙ 

 2x Ethernet (PRI/SEC) sockets, 1GBit

∙ 

 64x64 channel Brooklyn II board built-in

ADAT I/O
(Only Verto 32 & 64)

∙ 

 4x ADAT Input + 4x ADAT Output, optical TOSLINK (Verto 32)

∙ 

 32x32 channels at 48kHz, 16x16 channels at 96kHz

∙ 

 8x ADAT Input + 8x ADAT Output, optical TOSLINK (Verto 64)

∙ 

 64x64 channels at 48kHz 32x32 channels at 96kHz

MIDI I/O

 MIDI Standard 1.0 / 1996

∙ 

 2x DIN female 5pin In/Out for embedding / de-embedding  
MIDI-over-MADI messages

MADI I/O
(Verto MX only)

∙ 

 AES 10, 2x optical LC port, 2x coaxial BNC port

∙ 

 64x64 channels at 48kHz, 32x32 channels at 96kHz, 16x16 
channels at 192kHz

Wordclock

∙ 

 2x BNC In/Out, 75 Ohm termination set to on by default.  
Can be changed from software via DANTE.

Fuse

∙ 

 Polyfuse internal, self-resetting

Power consumption

∙ 

 14.4VA (1.2A at 12V)

Temperature range

∙ 

 +5°C to +45°C

Humidity

∙ 

 <75%,  non-condensing

Dimensions

∙ 

 22 x 9 x 4,5 mm (without rack ears)

Weight

∙ 

 0,9  kg

07. Optional accessories and spare parts

The following accessories and spare parts are available for the Verto series:

Description

Item code

For VERTO Series

19“ Rack mountain kit, metal 
(for mounting 1 x Verto in a 19” rack-space)

7008 

32, 64 and MX

Multi-range Power Supply 12V (EU)

7023 

32, 64 and MX

ADAT Cable Locking Plate

7027 

32 and 64

MADI Singlemode Module 

7020 

MX

MADI SC / LC Adapter 

7026 

MX

The accessories and the spare parts can be purchased 
from the dealer or the distributor as well as at 

www.ferrofish.de

.

Summary of Contents for Verto 32

Page 1: ...OWNERS MANUAL Version 1 0 Ferrofish Advanced Audio Applications Brüderstr 10 D 53545 Linz Rhine Germany www ferrofish de ...

Page 2: ...rear panel 7 04 2 1 Verto 32 and 64 7 04 2 2 Verto MX 8 04 3 Clocking 8 05 Operation important 8 06 Technical specifications 9 07 Optional accessories and spare parts 9 08 Troubleshooting 10 09 Legal information 11 09 1 Warranty 11 09 2 Disclaimer of liability 11 10 Declarations of conformity etc 12 10 1 CE conformity EMC 12 10 2 CE conformity RoHS II 12 10 3 FCC Declaration 12 10 4 Waste disposal...

Page 3: ...re are important maintenance and operating instructions in the literature This symbol warns the user of uninsulated potentially dangerous voltage inside the unit that can cause an electric shock This symbol warns the user that the output connectors of the power supply contain voltages that can cause dangerous potentially lethal shocks ...

Page 4: ...he device has been damaged in any way For example when liquids have been spilled on the device objects have fallen onto it or the device itself has been dropped Servicing is also essential when the device no longer functions normally or has been exposed to rain or moisture 10 This unit generates heat during normal operation Use it in a well ventilated environ ment with at least 1RU space between a...

Page 5: ...ansmit 64x64 audio channels plus MIDI commands up to 2km with the Multimode MADI module It is even possible to bridge distances of up to 10km via MADI glass fiber with the optional sin gle mode MADI module installation of which can easily be done by the end user We sincerely hope that you will enjoy using your Verto as much as we enjoyed devel oping it Should you have any suggestions praise or cri...

Page 6: ... rate in the DANTE network 2 ADAT Inputs Verto 32 1 4 Verto 64 1 8 These status LEDs indicate when an ADAT input has been successfully synchronized to the DANTE network s word clock These LEDs are not input indicators If the LED flashes the synchronization process has failed If it is lit continuously interrupted by short flickering both devices are master 3 Power LED The LED lights up continuously...

Page 7: ...ghts up continuously when the device is switched on and ready for operation It flashes slowly when the device is booting If you hold down the pow er button the LED will rapidly flash to indicate the imminent shutdown of the device 6 Power button This button turns the Verto on and off To switch off the unit press and hold the button for at least 3 seconds If a valid MADI signal is present on the op...

Page 8: ... WORDCLOCK I O Transmit word clock to or from the Verto using these connectors We recommend setting the connected devices to slave 6 DANTE PRI SEC Use this port to connect the unit to a DANTE network Use a com mercially available Ethernet cable at least CAT5 and connect it to the PRI primary port 04 3 Clocking important Generally in a network of DANTE devices at least one of them must be set to ma...

Page 9: ...dclock 2x BNC In Out 75 Ohm termination set to on by default Can be changed from software via DANTE Fuse Polyfuse internal self resetting Power consumption 14 4VA 1 2A at 12V Temperature range 5 C to 45 C Humidity 75 non condensing Dimensions 22 x 9 x 4 5 mm without rack ears Weight 0 9 kg 07 Optional accessories and spare parts The following accessories and spare parts are available for the Verto...

Page 10: ...t approximately 20s until the boot process is finished Error in the DANTE network Check the functioning of the DANTE network DANTE LED is flashing No connection to the Dante network Check the functioning of the DANTE network Device is slave but no Mas ter was found on the DANTE network Set a device in the DANTE net work to Master Sample rate on the network has been changed When changing the sample...

Page 11: ...y either expressed or implied for the accuracy completeness and correctness of this documentation In no event Ferrofish GmbH will be liable for any kind of data loss or data error caused thru the use of our product or documentation In particular Ferrofish GmbH excludes liability upon consequential damage caused by the use of this product or the documentation All trademarks used in this manual are ...

Page 12: ...o comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential in stallation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications...

Page 13: ... and or end of its lifetime In case a disposal of electronic waste is not possible the recycling can also be done by the manufacturer For this the device has to be sent free to the door to Ferrofish GmbH Brüderstraße 10 D 53545 Linz Rhein Germany Not prepaid shipping s will be rejected and returned on the sender s costs 10 6 Service Maintenance No serviceable parts inside Do not open this device ...

Page 14: ...14 NOTES ...

Page 15: ...15 ...

Page 16: ...ns or other changes to this unit not approved by the party responsible for compliance could void the user s authority to operate this equipment 10 4 Waste disposal WEEE 10 5 Maintenance 10 6 Service Ferrofish Advanced Audio Applications Brüderstr 10 D 53545 Linz Rhine Germany www ferrofish de ...

Reviews: