22
Basic Maintenance
6.1 Test for checking if there is air in the Ferret inflation system
Step 1.
Install the Green Cap on
the end of the Ferret Pipe.
Step 2.
Slowly turn the Ferret
Pump clockwise (+)
to increase the pressure in
the Ferret inflation system
whilst watching the Ferret
Pressure Gauge.
IMPORTANT:
If there is no air in the Ferret
inflation system you should
be able to achieve a pressure
reading of 4 bar (60 psi)
with no more than one full
turn of the Ferret Pump.
If there is air in the
system remove it by
following the instructions
on the next page.