HEATING MODEL TECHNICAL PARAMETER

       POWER

ITEM

SINGLE PHASE

( 230V~

MAIN LINE:L

N)

THREE PHASES

( 400V~ MAIN LINE:A

B

C

N) 

HEATER
POWER

kW

3

4

5

6

8

10

14

3

4

5

6

8

10

14

MAIN 
LINE

mm

2

1.5

2.5

2.5

4.0

6.0

10

10

1.0

1.0

1.0

1.5

2.5

2.5

4.0

EARTH LINE
(mm

2

0.75

1.0

1.0

1.5

2.5

2.5

4.0

0.75

0.75

0.75

0.75

1.0

1.0

2.5

W

H

I

T

E

BLUE(BROWN/RED)

YELLOW

c

MOTOR

ORANGE

(YELLOW)

B

L

A

C

K

Y

E

L

L

O

W

-

G

R

E

E

N

RECEIVER

IC

HEATER

HEATER

B C

N A

PN

THERMAL CUT-OUT

THERMAL CUT-OUT

THERMAL CUT-OUT

on

com

1

2

com

on

on

com

3

I/O

RECEIVER

BROWN
BLUE

WHITE

GREY

YELLOW-GREEN

W

H

I

T

E

BLUE(BROWN/RED)

YELLOW

c

MOTOR

ORANGE

(YELLOW)

B

L

A

C

K

Y

E

L

L

O

W

-

G

R

E

E

N

RECEIVER

IC

HEATER

HEATER

L

N

PN

THERMAL CUT-OUT

THERMAL CUT-OUT

THERMAL CUT-OUT

on

com

1

2

com

on

on

com

3

I/O

RECEIVER

BROWN
BLUE

WHITE

GREY

YELLOW-GREEN

7

OPERATION 

7.1. Controlled by remote controller 

a. Press “ON/OFF” button to turn ON the unit. Main receiver receives the signal with the sound of “beep” to start

working with the green light in cool mode at high speed “H”. Press “ON/OFF” button again to turn OFF. 

b. When the unit is working at the above a. situation, press “COOL” button in the Remote controller, receiver receives

the signal with the sound of “beep” and switch high speed to low speed “L”. Meanwhile there is a green light
display in the receiver. Press “COOL” button again, the unit will switch low speed to high speed. So when the unit
is working at cool mode, press “COOL” button can switch air curtain working under the cycle of Low or High
speed. 

c. FOR SINGLE PHASE UNIT

: When the unit is working at the above b. situation, press “HEAT” in the remote

controller, receiver receives the signal with the sound of “beep” and switch cool mode to heating mode at low
power. Meanwhile there is a Red light display in the receiver. Press “HEAT” button again, the unit will switch low
power to high power. Meanwhile there is TWO Red lights display in the receiver. Press “HEAT” button again, the
unit will switch heating mode to cool mode and the red lights display change to green light in the receiver. So when
the unit is working at cool mode, press “HEAT” button can switch air curtain working under the cycle of heating
low power, heating high power or cool mode. 

LINE SIZE

FK90E3 

FK120E3 

FK150E3 

FK200E3 

FK90E 

FK120E 

FK150E 

FK200E

160 

200 

230 

350 

160 

200 

230 

350

  2 

2.7 

3.3 

4.6 

  3 

  4 

  5 

  7

  4 

5.3 

6.7 

9.4 

  6 

  8 

 10 

 14

 6 

 8 

10 

14 

  - 

  - 

  - 

  -

115

115

400/50

230/50

35-45            8.5

35-45            8.5

1000 

1500 

1900 

2800 

1000 

1500 

1900 

2800

55-57 

56-58 

57-59 

59-61 

55-57 

56-58 

57-59 

59-61

14.5 

  17 

  22 

  26 

14.5 

  17 

  22 

  26 

MODEL

 Diam. 

   Of 

Wheel 

(mm)

Voltage 

  /Freq. 

(V

/Hz)

Motor 

Power 

  (W)

 

Heater power 

       (KW)

I

II

III

Temp. 

  (K)

Max.air 

  speed 

  (m/s)

   Air 

volume 

(m3/h)

Noise 

 (dB)

  Net 

weight 

 (Kg)

Summary of Contents for FK90E3

Page 1: ...USER MANUAL Air curtain with an electric heater Models FK90E3 FK120E3 FK150E3 FK200E3 FK90E FK120E FK150E FK200E www ferono com info ferono com ...

Page 2: ...of air curtain Note code of improved design of Y type of wireless remote control D type of AC electrical heating D single phase 3D three phases 3 IDENTIFICATION INSTALLATION DIMENSIONS 4 INSTALLATION CAUTION Must follow the following requests when installing air curtain 4 1 Please install the unit in a sturdy place to avoid the shaking and ensure its security because it maybe causes the wall becom...

Page 3: ...exposed to excessive steam explosive gas or corrosive gas 5 INSTALLATION A Installing on the concrete wall 5 1 1 Removed the mounting plate Unclamping the fixed screws on the back of main body to removed the mounting plate MO UNTIN G PIATE FIXI NG SCRE W 5 1 2 Fix the bolts in the proper position Fix the position with the mounting plate and pour cement into the bolt holes CONC RETE 13 15mm 70mm φ4...

Page 4: ... the ceiling brackets and ensure safe fixing use the bolts attached to the ceiling brackets as Fig Using the ceiling brackets to hang from the ceiling the position of mounting plate can be adjusted in the limit of 100mm 5 3 4 Do the same as step A to install the main body 5 2 1 Fix the mounting plate in the proper positions with tapping screw MOODEN SCREW MOUN TING PI ATE 5 2 2 Same as the step 5 ...

Page 5: ...Meanwhile there is a green light display in the receiver Press COOL button again the unit will switch low speed to high speed So when the unit is working at cool mode press COOL button can switch air curtain working under the cycle of Low or High speed c FOR SINGLE PHASE UNIT When the unit is working at the above b situation press HEAT in the remote controller receiver receives the signal with the...

Page 6: ...ntrol panel in the unit is the same function as 7 1 7 3 Overheat protection When the air curtain works at heating mode there is overheat protection When the heater temperature is overheating heating mode will stop and switch to cool mode automatic at the same time the indication light change to green light When the temperature drop down to a certain temperature if want the unit to work at heating ...

Page 7: ...e warranty is valid only with invoice Air curtain model Serial number Sale date Invoice number Service sign and stamp Instalation date Instalation adress Electrical permission number Service sign and stamp CONFIRMATION OF INSTALLATION BY AUTHORIZED SERVICE ...

Page 8: ......

Reviews: