background image

ECOUNIT F

24

Cod. 30902340  -  Rev. 03 - 09/2015

EN

ELECTRICAL HEATING ELEMENT (1500W - 230V)

The heating element can be used as an auxiliary DHW heating system or as an antifreeze system. In the latter case, set the 

heating element adjustment knob (“

A

” - “fig. 1”) to min. (15°). To use it for heating water, the thermostat knob “

A

” adjusts the 

heating temperature (set point) of the heating element, adjustable between 15 and 75 °C.
The electrical system must be installed by a qualified technician according to the local regulations and in accordance with the 

applicable regulations in the building.

The system heating element must not be activated with the hot water tank empty! In this case the heating element 

warranty is voided.

For the heating element electrical connection (see “fig. 1”):

- Remove the cover "

D

" by removing the screws.

- For the connection of the hot water tank heating element to the power supply, a cable “

B

” 3 x 2.5 mm2 (for 1.5 kW heating 

element) is required.

- Run the end of the cable from the cable gland to the electrical part.
- Connect the wires to the terminals of the thermostat “

C

”. Reassemble everything.

Make sure the thermostat is properly applied to the heating element.

The thermostat temperature adjustment range is from 15°C to 75°C. The thermostat has a safety device which intervenes if 

the temperature exceeds 93°C.

 

fig. 1

3. Operating instructions

STARTUP

After installation, fill the hot water tank with water for DHW use and for heating, proceeding as follows:
•  Carry out filling of water for heating and vent the system

•  Carry out filling of water for DHW use by means of the cold water inlet and vent by opening a hot water drawing point

• 

Install the thermostatic device in the special place on the hot water tank

• 

Start the boiler

• 

Emptying the unit

•  To carry out emptying, close the cock for filling from the water system, connect a hose to the drain union and place the other 

end in an area provided with an external drain

• 

Open a drawing point and let the water run, then open the drain union and complete the emptying.

Summary of Contents for ECOUNIT 2C Series

Page 1: ...ECOUNIT F 1C 2C INSTRUZIONI PER USO INSTALLAZIONE E MANUTENZIONE INSTRUCCIONES DE USO INSTALACIÓN Y MANTENIMIENTO USE INSTALLATION AND MAINTENANCE INSTRUCTIONS Cod 30902340 Rev 03 09 2015 30902340 ...

Page 2: ...e d uso 4 4 Manutenzione e pulizia 5 5 Dati Tecnici 5 1 Advertencias generales 13 2 Presentación 13 3 Normas de uso 14 4 Mantenimiento y limpieza 15 5 Datos técnicos 15 1 General instructions 23 2 Introduction 23 3 Operating instructions 24 4 Maintenance and cleaning 25 5 Technical Data 25 ...

Page 3: ...cteristics and power PLACE OF INSTALLATION The place of installation must be protected against frost The hot water storage tank must be placed in the immediate vicinity of the heat generator to avoid pointless heat loss Suitably insulate the feed pipes PLUMBING CONNECTIONS Carry out the relevant connections according to the cover diagram and the symbols given on the unit It is advisable to install...

Page 4: ...or 1 5 kW heating element is required Run the end of the cable from the cable gland to the electrical part Connect the wires to the terminals of the thermostat C Reassemble everything Make sure the thermostat is properly applied to the heating element The thermostat temperature adjustment range is from 15 C to 75 C The thermostat has a safety device which intervenes if the temperature exceeds 93 C...

Page 5: ...ry Refill the unit according to the startup instructions and check its tightness ANODE CHECK The unit is protected against corrosion by a vitreous enamel coating of the inner surface and the exchange coil The hot water tank also has an anticorrosion magnesium anode to protect against the effect of eddy currents which could damage it the duration depends on operation and the quality of the water Th...

Page 6: ...OUNIT F 150 1C 500 1325 1216 1088 988 888 336 236 126 400 326 ECOUNIT F 200 1C 540 1453 1344 1084 984 884 334 234 124 440 324 ECOUNIT F 300 1C 620 1535 1431 1161 1061 961 361 261 131 520 351 ECOUNIT F 400 1C 750 1469 1326 985 885 785 441 341 155 650 418 ECOUNIT F 500 1C 750 1769 1626 1261 1161 1061 441 341 155 650 418 Plumbing connections Model DHW connections Coil connections Recirculation connec...

Page 7: ... 2C 540 1453 1344 1234 1134 1034 934 834 734 234 124 324 440 324 ECOUNIT F 300 2C 620 1535 1431 1311 1211 1111 961 861 761 261 131 351 520 351 ECOUNIT F 400 2C 750 1469 1326 1174 1074 974 852 752 661 391 291 155 650 418 ECOUNIT F 500 2C 750 1769 1626 1474 1374 1274 1152 1052 898 398 298 155 650 418 Plumbing connections Model DHW connections Upper coil connections Lower coil connections Recirculati...

Page 8: ...obe 6 Boiler outlet 7 Cold water inlet 11 Hydraulic safety valve not supplied 12 Emptying cock not supplied 13 Discharge pipe not supplied 14 Expansion tank not supplied 15 Pressure reducer not supplied 16 Non return valve optional not supplied 17 Shutoff valve optional not supplied 18 Pump optional not supplied 19 Boiler not supplied 20 Recirculation piping optional not supplied ...

Page 9: ...e 9 Solar inlet 10 Solar outlet 11 Hydraulic safety valve not supplied 12 Emptying cock not supplied 13 Discharge pipe not supplied 14 Expansion tank not supplied 15 Pressure reducer not supplied 16 Non return valve optional not supplied 17 Shutoff valve optional not supplied 18 Pump optional not supplied 19 Boiler not supplied 20 Recirculation piping optional not supplied 21 Hydro assembly 12 not...

Page 10: ...IT F 300 2C ECOUNIT F 400 2C ECOUNIT F 500 2C Capacity litres 178 275 385 478 UPPER COIL Exchanged power t 35 K kW 12 5 18 29 6 29 6 DHW flow rate t 35 K litres h 306 444 726 726 DHW flow rate t 50 K litres h 216 310 510 510 Preparation time t 35 K min 39 41 33 41 Preparation time t 50 K min 56 58 47 59 Coil exchange surface m2 0 5 0 72 1 19 1 19 Coil length m 6 38 9 17 11 43 11 43 Coil pressure l...

Page 11: ...150 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 130 EN FERROLI 92 ECOUNIT F 200 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 180 EN FERROLI 92 ECOUNIT F 200 2C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 178 EN FERROLI 112 ECOUNIT F 300 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 277 EN FERROLI 112 ECOUNIT F 300 2C FERROLI S p...

Page 12: ...FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 385 EN FERROLI 143 ECOUNIT F 500 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 480 EN FERROLI 143 ECOUNIT F 500 2C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 478 EN FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli it ...

Reviews: