Ferno AS-190 User Manual Download Page 2

© Ferno-Washington, Inc. / 234-2124-03 / May 2018

2

Lot Number _________________________
Location: One strap of each splint

USERS’ MANUALS 

To request additional free users’ manuals, 

contact Ferno Customer Relations, your Ferno 

distributor, or 

www.ferno.com

.

Disclaimer

This manual contains general instructions for the use, operation 

and care of this product. The instructions are not all-inclusive. Safe 

and proper use of this product is solely at the discretion of the user. 

Safety information is included as a service to the user. All other safety 

measures taken by the user should be within and under consideration 

of applicable regulations and local protocol. Training on the proper use 

of this product must be provided before using this product in an actual 

situation.
Retain this manual for future reference. Include it with the product in 

the event of transfer to new users. Additional free copies are available 

upon request from Customer Relations.

Proprietary Notice

The information disclosed in this manual is the property of Ferno-

Washington, Inc., Wilmington, Ohio, USA. Ferno-Washington, Inc. 

reserves all intellectual property rights, proprietary design rights, 

manufacturing rights, reproduction use rights, and sales use rights 

thereto, and to any article disclosed therein except to the extent those 

rights are expressly granted to others or where not applicable to vendor 

proprietary parts.

Limited Warranty Statement

The products sold by Ferno are covered by a limited warranty, which 

is printed on all Ferno invoices. The complete terms and conditions of 

the limited warranty, and the limitations of liability and disclaimers, 

are also available upon request by calling Ferno at 1.800.733.3766 or 

1.937.382.1451.

Ferno Customer Relations

For ordering assistance or general information:

CANADA AND THE U.S.A.

Telephone (Toll-free) 

1.877.733.0911

Telephone  

1.937.382.1451

Fax (Toll-free) 

1.888.388.1349

Fax 1.937.382.1191

Internet www.ferno.com

ALL OTHER LOCATIONS

For assistance or information, please contact your Ferno distributor. If 

you do not have a Ferno distributor, please contact Ferno Customer 

Relations:

Ferno-Washington, Inc., 70 Weil Way 

Wilmington, Ohio 45177-9371, U.S.A.

Telephone  

Country Code +1.937.382.1451

Fax 

Country Code +1.937.382.6569

Internet www.ferno.com

1.937.382.1451

44 (0) 1274 851999

Summary of Contents for AS-190

Page 1: ...Users Manual May 2018 Pub No 234 2124 03 Read this Manual and Retain for Future Reference Model AS 190 Vacuum Splints...

Page 2: ...lmington Ohio USA Ferno Washington Inc reserves all intellectual property rights proprietary design rights manufacturing rights reproduction use rights and sales use rights thereto and to any article...

Page 3: ...4 3 Disconnecting the Pump_____________________________ 8 5 Using the Splints________________________________________ 9 5 1 Before Placing the Splints In Service____________________ 9 5 2 General Guid...

Page 4: ...Disease Notice To reduce the risk of exposure to bloodborne diseases such as HIV 1 and hepatitis when using the splints follow the disinfecting and cleaning instructions in this manual 1 4 Symbol Glo...

Page 5: ...AS 100 SPLINT SMALL Length 21 in 533 mm Width 14 in 345 mm Thickness 1 5 in 40 mm Weight 0 90 lb 408 g MODEL AS 120 SPLINT MEDIUM Length 29 in 735 mm Width 24 in 610 mm Thickness 1 5 in 40 mm Weight 1...

Page 6: ...se are included in the Model AS 190 vacuum splint set Components may also be purchased separately About the Splints Model AS 120 Splint CARRYING CASE MODEL AS 100 SPLINT MODEL AS 120 SPLINT MODEL AS 1...

Page 7: ...removable valve knob to the splint if separated and tighten securely Figure 1 2 Remove the valve plug tab from the removable valve knob and valve adapter from the pump hose if needed Figure 2 3 Insert...

Page 8: ...Disconnect the pump from the valve knob 2 Insert the valve plug tab into the knob to prevent air loss while the splint is in use Figure 4 4 2 Evacuating the Air Use the pump provided to evacuate the a...

Page 9: ...ollow standard emergency patient handling procedures when applying and operating the splints Applying a vacuum splint requires a minimum of two trained operators One operator manually stabilizes the i...

Page 10: ...ectthevacuumpumptothevalve Forcompleteinstructions see Connecting the Pump page 7 6 The pump operator begins evacuating the air from the splint by repeatedly squeezing the pump handle If the splint dr...

Page 11: ...nt 1 One operator manually stabilizes the injured area of the body throughout the splint removal procedure 2 The second operator unfastens the adjustment straps 3 Open the air valve by turning the val...

Page 12: ...a towel Allow the hook and loop fastening strips to air dry 3 Store only clean dry splints in the carrying case 6 3 Inspecting the Splints Have your service s equipment maintenance personnel inspect...

Page 13: ...4 hours for the patch to set in place 1 Clean and dry the area to be repaired 2 Cut the repair patch approximately 3 4 19 mm larger than the hole Round the corners of the patch 3 Apply the glue to the...

Page 14: ...s only as designed by Ferno 7 2 Parts List Description Kit Vacuum Pump 083 1965 Carrying Case 038 2916 Vinyl Repair Kit 083 1966 Model AS 190 Set of 3 Splints 037 4861 Model AS 100 Small Splint 037 48...

Page 15: ...Ferno Washington Inc 234 2124 03 May 2018 15 TRAINING RECORD Date Name Training Method MAINTENANCE RECORD Date Maintenance Performed By...

Page 16: ...Ferno Washington Inc 234 2124 03 May 2018...

Reviews: