Kit5000_GB-A
5 –
The manufacturer and / or installer must give each customer a file showing that the products used do not emit any
dangerous substance beyond the maximum authorized levels, specified in the appropriate European standards or in other
national specifications, in the event of fire
(EN 13241-1 §4.2.9).
6 –
The installer is required to ensure the traceability of assembly and inspection operations effectively carried out
(EN
13241-1 §6.4).
7 –
The staff of the company installing the equipment, and / or staff of the user company in charge of specific functions,
such as maintenance, must be qualified, trained and certified in the case of particularly risky work, such as work under
power
(D. Safety at work 89/655/EEC modified 95/63/EEC art.7 / CT art. R 233-2).
8 –
The final user must carry out the periodical yearly or twice-yearly checks, or have them carried out, with keeping of a
maintenance register
(
D. Safety at work - 89/655/EEC modified 95/63/EEC - art. 4b / CT R 233-1-2 and R 233-11-1).
9 –
The installation of a motorised system involves the implementation of safety dispositions in compliance with the
essential requirements of health and safety, decreed by the European directives and / or regulations in force in the
countries of installation
(EN12453 §5.1.1.6).
10 –
The installation of a motorised door in a blind place involves:
- either a second door (for persons to walk through)
- or a sound alarm in case of a person being trapped
(EN12453 §5.4.2).
11 -
The installation of a motorised door involves:
The installation of adequate lighting of the area where the door is installed to prevent any movement in darkness.
Marking out and signalling of the danger area, at floor level
(CT R232-1-13/ EN12453 §5.1.3).
- 4 -
2 - TRANSPORT
This equipment must be protected from bad weather during transport.
The original packing is designed for all types of transportation means.
The packed kit withstands stacking of 4 others automatic kits.
The liability of FERMOD ceases:
- as soon as the customer or installer opens the package or a part of the packaging,
- as soon as the package has suffered a considerable impact in such a way that it’s damaged.
3 - STORAGE
This equipment must be protected from bad weather during storage.
The packed kit withstands stacking of 4 others automatic kits.
4 - MOUNTING PRECAUTIONS
Please respect the regulations that apply in the country of installation.
The volume of door or gate opening must have sufficient lighting. A lighting level of 50 lux measured at floor level must be
ensured, and the opening area must be marked out on the floor. Any movement of the door or gate must be signalled by a
flashing orange light visible from both sides. In France, this marking and signalling must comply with the decree of
Article
R 232-1-13
of the code of labour
(decree of 21/12/1993).
In Europe, the manufacturer and / or the installer of the door must attach the plate of overall characteristics to the door, in
conformity with the instructions of standard
NF EN 13241-1- §4.6
.
Please refer to our mounting instructions.
- Check the temperature of the environment. For temperatures lower than –10°C, a low temperature command box is required.
- Check the compatibility between the Automatic Kit to be installed with the Fermatic Manual System.
- The door drive sub-assembly fixations must be well made and made of suitable material, having an appropriate resistance
and be exempt from any obvious fault for their intended working life (in conformity with
EN 12604:2000,4-2-1
).
- Electrical network: 220-240V AC - 50/60 Hz.
- Connection cable section : 3G2,5 mm².
- Connect each Kit to a dedicated power line protected by a circuit breaker D curve.
!