MARINE PANEL INSTALLATION
QUICK GUIDE
Cod. 970189 V09_20
CONNECTIONS
BASIC PROGRAMMING FROM A PC
ON-SCREEN INFORMATION
BASIC DIAGRAMS
POWER INPUT:
12 Vdc power supply for the cases
where no LAN PoE is available.
OUTPUT:
Electric lock control relay output.
• NC: Normally closed contact.
• NO: Normally opened contact.
• C: Common.
NOTE: NC & C contacts are internally duplicated.
EX PROXIMITY:
• (WD0-WD1) Wiegand input/output.
• (+5V, -) 5 Vdc auxiliar output.
EXIT BUTTON /FIRE / DOOR SENSOR:
• (EXIT, -) Connections for indoor button.
• (FIRE, -) Input for fire alarm & block doors unlock
contacts.
• (DS, -) Connection for door opened sensor.
RS485:
Output for Ref.1491 / Ref.1490 / Ref.1494/
Ref.9545 module.
RJ 45 NETWORK:
RJ 45 LAN connection.
Basic diagram using Switch PoE.
Use a power supply adapted to the electric lock voltage & current.
Basic diagram using no PoE switch
Supply the panel by means of a FERMAX Ref. 4813 (12 Vdc 2A) power supply.
Use a power supply adapted to the electric lock voltage & current.
Do not power the panel and the electric lock from the same power supply.
• Panel programming is done exclusively by means of a
PC connected to the same LAN, through of a web browser
(Chrome preferably), accessing the IP of the panel.
• Default IP is: 10.1.0.1.
• The PC must have an IP of the same range as the IP of the
panel.
Example: In the case that the IP of the panel is 10.1.0.1, the IP of
the PC have to be of type 10.X.X.X with a subnet mask 255.0.0.0
To login, identify yourself with the
username and password.
Default value:
• Username:
admin
• Password:
123456
• Assign, as a minimum, the parameters indicated in the following table.
• It is necessary to carry out a previous planning of the installation, to define the parameters
to assign to each device.
2. The screen will display
information about panel
settings:
• Firmware version
• GENERAL settings
• Serial number
• IP address
• MAC
1. Dial 9999,
followed by
the key “B”.
It is possible to get basic information on the equipment configuration through the screen.
GENERAL
1.LANGUAGE: Select the desired language (default
ENGLISH).
2.TYPE: Choose BLOCK PANEL or G.E. PANEL.
Depending on the selection the fields below will be
different
• If BLOCK PANEL
•
BLOCK: Block number
• DEVICE NO: Device number in the block. If
there is only one leave it in 1.
• If G.E. PANEL
• DEVICE NO: Entrance number in the installation.
If there is only one, leave it in 1.
3. SIP DIVERT MODE: PARALLEL CALL
Confirm with SAVE
NETWORK
Indicate the network parameters assigned to this panel:
• IP:
Panel IP address
• MASK:
Subnet mask
• GATEWAY:
IP of gateway
• DNS:
Valid DNS IP
Confirm with SAVE
Further information at meet.fermax.com