MARINE PANEL INSTALLATION 

QUICK GUIDE

Cod. 970189 V09_20

CONNECTIONS

BASIC PROGRAMMING FROM A PC

ON-SCREEN INFORMATION

BASIC DIAGRAMS

POWER INPUT: 

12 Vdc power supply for the cases 

where no LAN PoE is available.

OUTPUT:

 Electric lock control relay output. 

• NC: Normally closed contact.

• NO: Normally opened contact.

• C: Common.

NOTE: NC & C contacts are internally duplicated.

EX PROXIMITY:

• (WD0-WD1) Wiegand input/output. 

• (+5V, -) 5 Vdc auxiliar output. 

EXIT BUTTON /FIRE / DOOR SENSOR:

• (EXIT, -) Connections for indoor button.

• (FIRE, -) Input for fire alarm & block doors unlock 

contacts.

• (DS, -) Connection for door opened sensor.

RS485:

 Output for Ref.1491 / Ref.1490 / Ref.1494/ 

Ref.9545 module.

RJ 45 NETWORK: 

RJ 45 LAN connection.

Basic diagram using Switch PoE.

Use a power supply adapted to the electric lock voltage & current.

Basic diagram using no PoE switch

Supply the panel by means of a FERMAX Ref. 4813 (12 Vdc 2A) power supply.

Use a power supply adapted to the electric lock voltage & current.

Do not power the panel and the electric lock from the same power supply.

•  Panel  programming  is  done  exclusively  by  means  of  a 

PC connected to the same LAN, through of a web browser 

(Chrome preferably), accessing the IP of the panel.

• Default IP is: 10.1.0.1.

• The PC must have an IP of the same range as the IP of the 

panel. 

Example: In the case that the IP of the panel is 10.1.0.1, the IP of 

the PC have to be of type 10.X.X.X with a subnet mask 255.0.0.0

To login, identify yourself with the 

username and password.

Default value:

• Username: 

admin

• Password:

 123456

• Assign, as a minimum, the parameters indicated in the following table.

• It is necessary to carry out a previous planning of the installation, to define the parameters 

to assign to each device.

2. The screen will display 

information about panel 

settings:

• Firmware version

• GENERAL settings

• Serial number

• IP address

• MAC

1. Dial 9999, 

followed by 

the key “B”. 

It is possible to get basic information on the equipment configuration through the screen.

GENERAL

1.LANGUAGE: Select the desired language (default 

ENGLISH).
2.TYPE:  Choose  BLOCK  PANEL  or  G.E.  PANEL. 

Depending on the selection the fields below will be 

different

• If BLOCK PANEL

• 

BLOCK: Block number

• DEVICE  NO:  Device  number  in  the  block.  If 

there is only one leave it in 1.

• If G.E. PANEL 

• DEVICE NO: Entrance number in the installation. 

If there is only one, leave it in 1.

3. SIP DIVERT MODE: PARALLEL CALL
Confirm with SAVE

NETWORK

Indicate the network parameters assigned to this panel:

• IP:

 Panel IP address

• MASK:

 Subnet mask

• GATEWAY:

 IP of gateway

• DNS: 

Valid DNS IP

Confirm with SAVE

Further information at meet.fermax.com