QUICK PROGRAMMING GUIDE
1. ENCODING PANELS
Whenever there are
more
than one panel (to a block) you must program the
panel
number
, but for this you need key 7439.
5 way cable
Connecting the keypad:
a)
With the disconnected power, use the 5 way cable to connect the keypad as shown in
the diagram.
b)
Reconnect the power supply. Now you can program the required parameters with the
keypad.
c)
Before performing the operation to disconnect the keypad, remove the power.
9
8
7
6
5
4
3
2
1
A
B
0
The entry panel's parameters can be programmed on the keypad.
1.1 Access programming:
A + 4444
(default code).
If the code is correct, a confirmation tone sounds (beep-beep).
1.2 Configuring the different parameters
The configuration of a parameter is done by entering:
two digits of its position,
and a
beep is heard and the
desired value
(1,2,3 or 4 digits relative to the parameter function).
If the value is correct, a confirmation tone sounds (beep-beep) and the new value is
saved. If not correct you will hear the error sound (beep-bop).
In order to exit the programming press 'A' when we are entering the menu's parameter
number. You can also exit by waiting 60 seconds without pressing any key.
Configuration of a parameter:
A + access code for progr po possible values
ON
DL2
EXIT
MIC
AUDIO
AMPLIFIER
AMPLIFICADOR
DUOX
PACK EXTENSION
B
D
A
C
E
LANGUAGE
IDIOMA
18Vdc
SW1 PROG
CN9 TAMPER
CN1
LED
DL2
ONE
P2
+
B
B
+12
C
NC
NO
-
BS
S
P1
C
NC
NO
F
BUS
GND
CN3
CN2
TO
ONE
VERSION
:
SW1
CN9
CN1
CN1
CN1
ENTRADA/INPUT
ARRIVÉE/EINTRITT
CN1
UP
SALIDA/OUTPUT
SORTIE/AUSGANG
CN2
MÓDULO TECLADO
KEYPAD MODULE
MODULE CLAVIER
TASTATURMODUL
PUT
NTRITT
CN1
CN1
Configuration of a panel number:
A + 4444 + 06 + 0-9
Example:
•
Change panel number 2:
A 4444 (beep-beep) 06 (beep) 2 (beep-beep)
PROGRAM THE PANEL NUMBER
,
2
MARCAR TIPO
NÚMERO
SB
BK
EG
BK SB PL
PL 2
Panel number
Position
06
Adjustments Parameter Possible Values [default]
Comments
Panel No. (PL)