Fermax ACMAX BOX-IP Installer Manual Download Page 6

 

 

Cod. 970075        V06_19 

 

 

6/8 

 

I

NTRODUCTION

 

BOX-IP-15/16 metal enclosure is dedicated to installation of ACMAX modules and devices which require DIN 
rail and 7Ah (BOX-IP-15 in ref.5223 not included in the kit) and 17Ah (BOX-IP-16 in ref.5224 not included in 

the kit) backup battery. The enclosure is equipped with DIN rail, tamper contact and mounting bracket for 
PWR2D/PWR4D (ACMAX) power supply units. The enclosure front panel is attached with screws. BOX-IP-
15/16 is made of white powder coated stainless metal sheet. 

I

NSTALLATION

 

1.

 

The enclosure must be installed indoors ensuring nominal environmental conditions as stated in the 
Specification section. 

2.

 

All installation and maintenance works must be done with 230Vac power supply disconnected. 

3.

 

Power supply must be ensured with three wire cable including green-yellow PE.  

4.

 

Dismount F bracket with G screws prior to feeding mains power supply cable into enclosure. 

5.

 

Mains power supply cable must be fed into the enclosure through hole B when bracket is dismounted. 

6.

 

L and N cable wires must be connected to adequate terminals of the PWR while green-yellow PE wire 
must be connected to terminal C of the enclosure. 

7.

 

Cable I which is connected to electrode A must be connected to PWR

’s terminal

 with   symbol. 

8.

 

H connector must be connected to enclosure door. 

9.

 

The PWR in the enclosure is dedicated to continuous operation and is not equipped with on/off switch. 
Therefore, it is necessary to ensure overload protection in power supply circuit e.g. by applying and 

indicating dedicated fuse in fuse box. 

10.

 

The user of system must be acquainted with power disconnection rules and conditions. 

11.

 

PWR DC power output must be connected to adequate terminals of supplied device using included 
cables.  

12.

 

Other connections must be done in accordance with manuals of installed devices. 

13.

 

Connection cables for installed devices must be fed into enclosure through hole D. 

14.

 

Starting, configuration and adjustments must be done in accordance with system procedures after 

connection of 230Vac power supply. 

15.

 

Close the enclosure when installation and starting works are finished. 

 

 

Caution 

The installation can be done only by qualified person with all necessary 

certificates concerning connection and maintenance of 230Vac and low 

voltage networks. 

 

Caution 

It is forbidden to use the enclosure without properly executed and 

operational earthing system.

 

 

Caution 

Earthing system must be executed carefully, properly and effectively.  

It is forbidden to use the PWR without properly executed electric shock 

protection. 

 

Summary of Contents for ACMAX BOX-IP

Page 1: ...SISTEMA DE CONTROL DE ACCESO AC MAX Caja met lica BOX IP Manual de instalador C d 970075 Versi n del producto 1 0 Versi n de documento Rev A...

Page 2: ...limentaci n con el s mbolo 8 El conector H debe estar conectado a la puerta de la caja 9 La fuente de alimentaci n de la caja est destinada al funcionamiento continuo y no est equipada con un interrup...

Page 3: ...de PE B Orificio para cable de alimentaci n de 230 VCA C Protecci n contra descargas el ctricas Terminal de PE D Orificio para cables de comunicaci n del dispositivo E Contacto de manipulaci n F Sopor...

Page 4: ...L AC MAX 2 4 PUERTAS cumple con los requisitos de la Directiva RED 2014 53 UE y de la Directiva RoHS 2011 65 EU Ver p gina web www fermax com FERMAX Avd Tres Cruces 133 46017 Valencia Spain https www...

Page 5: ...Cod 970075 V06_19 5 8 ACMAX ACCESS CONTROL SYSTEM BOX IP metal enclosure Installer Manual Cod 970075 Product version 1 0 Document version Rev A...

Page 6: ...ich is connected to electrode A must be connected to PWR s terminal with symbol 8 H connector must be connected to enclosure door 9 The PWR in the enclosure is dedicated to continuous operation and is...

Page 7: ...Cod 970075 V06_19 7 8 Fig 1 Arrangement of BOX IP 15 internal components Fig 2 Arrangement of BOX IP 16 internal components BOX IP 15 BOX IP 16 PWR...

Page 8: ...5223 5224 is in compliance with the essential requirements of Directive RED 2014 53 UE and Directive RoHS 2011 65 UE See website www fermax com FERMAX Avd Tres Cruces 133 46017 Valencia Spain https w...

Reviews: