Ferm Accudrill FCD-1800I User Manual Download Page 3

ELECTRICAL INFORMATION

This product is complete with a pre-wired mains plug, it
is double insulated in accordance with EN 60335 – no
earth wire is required
If the plug needs replacing follow these instructions.

Wire correctly 

The wires in the mains lead are coloured in the following
way:

BLUE

-Neutral 

BROWN

-Live 

Securing wires

Secure wires carefully and firmly to the correct termi-
nals. Secure the mains cable in the plug cord grip firmly
Fit a 5-amp fuse. If a 13amp (BS1363) plug is used a (BS
1362) ASTA approved 5-amp fuse must be fitted.

Recycle/Dispose of old plug and cable 

Prevent inadvertent connection to socket and risk of
electric shock. 

If in doubt always consult a Qualified

Electrician

ENVIRONMENT

Recycle the packaging according to the identification
marks on it. At the end of the product or its accessories
life please recycle where facilities exist.

NiCd batteries are recyclable, take them to a local recy-
cling station or phone the Helpline for current advice on
recycling.

Helpline

For any questions relating to operational or safety
matters contact:

Ferm Customer Helpline on:

0115 966 1199

Monday-Friday

8am – 6pm

Saturday 

9am – 1 pm

GUARANTEE

The guarantee conditions can be found on the separately
enclosed guarantee card.

We declare under our sole responsibility that this 

product is in conformity with the following 

standards or standardized documents

prEN50260-1, prEN50260-2-1, prEN50260-2-2,

EN55014-1, EN55014-2,

EN60335-1,EN60335-2-29, 

EN61000-3-2, EN61000-3-3.

in accordance with the regulations.

98/37EEC, 

73/23/EEC, 
89/336EEC

from 01-09-2001

GENEMUIDEN NL

W. Kamphof
Quality department     

CE

ı

DECLARATION OF CONFORMITY

(UK)

Blue

(Neutral)

Green & Yellow

(Earth)

Brown

(Live)

Fuse

(5 Amp)

6

Ferm

OPERATIONAL SAFETY

Warning! 

The battery is normally sealed but in

event of the battery being damaged be aware that

it contains acid, if you get any on your skin or in your eyes wash
the affected parts with water immediately and seek medical
advice as soon as possible.

Warning! 

Do not short circuit the battery it will

cause it to overheat, catch fire or even explode. To

avoid this happening: Do not connect wires to the terminals of
the battery. Do not expose the battery or drill to water, rain or
damp atmospheres. Ensure that no metal objects (coins, nails
etc) are caught in the battery housing or battery socket in the
drill. Do not throw or dispose of the battery into water or fire.

Concentrate 

Routine and repetition can lead to mistakes. Remember
that a slight lack of concentration can result in serious
injuries in a split second.

Keep work area clean

Cluttered areas and benches invite injuries

Consider the work environment 

Do not expose power tools to rain or use them in damp
or wet locations. Keep work area well lit. Do not use
power tools in the presence of flammable liquids,
vapours or gases.

Guard against electric shock 

This unit and its charger contain dangerous voltages. Use
a RCD (residual current device) to provide protection
against electrical shock. Prevent body contact with
grounded surfaces (e.g. pipes, radiator, ranges or refrige-
rators)

Keep children and pets away

Do not let children or pets come into contact with the
tool, extension cable or work area.

Do not force the tool

It will work better and safer at the rate for which it was
intended,

Use the right tool

Do not force small tools or attachments to do the job of a
heavy-duty tool. Do not use tools for purposes for which
they were not intended; for example do not use a circular
saw for cutting trees or logs.

Do not abuse cable

Never carry the tool by the cable or pull it to disconnect
it from the power socket. Keep the cable away from heat,
oil and sharp edges. Do not touch the metal plug pins
when connecting or removing the plug.

Secure Work

Use clamps or a vice to hold work. It is safer than using
your hand and it frees both hands to operate the tool.

Do not over-reach

Keep a proper footing and balance at all times.

Disconnect tools from power supply

When not in use, before servicing and when changing
accessories such as blades, bits and cutters.

Always remove the battery and set the direction
switch to lock position. Always switch off and

unplug from the power supply before making adjustments or
inserting batteries into charger unit. Remove adjusting keys
and wrenches. Ensure that they are removed from the tool
before switching on.

Avoid unintentional starting

Do not carry plugged in tools with your finger on the
switch. Check that the switch is off before plugging in to
socket.

Extension cables

Use only three core earthed extension cables suitable
for the power input of the tool (minimum cable size
1.5mm2).  Plug into an earthed socket only. 
When using a cable reel unwind it fully. Do not use long
extension cables.

Outdoors use

If the tool is suitable to be used outdoors, only use an
extension cable intended for outdoor use and marked
accordingly. Use a RCD (residual current device) to pro-
vide protection against electrical shock.  Do not use in
rain or damp conditions.

Connect a dust extraction device 

Whenever there are facilities for fitting a dust of fume
extraction system, make sure it is connected and used.

Use recommended accessories

The use of any other accessory or attachment other than
recommended in the instructions or catalogue may pre-
sent a risk of personal injury. 

USING THE ACCUDRILL

BEFORE OPERATING

Warning! 

Before using this drill check carefully for

hazards, for example when drilling walls make sure

you do not contact with electrical wires, water pipes or asbe-
stos. If asbestos is present, cease operations and contact your
local council for advice. 

-

Check that the voltage marked on the charger is sui-
table for use with your mains supply.

-

The output voltage on the charger is suitable to use
with the drill battery.

-

The battery voltage is suitable for the drill.

The battery supplied with the drill is not fully char-
ged.

Ferm

3

Reviews: