5
EN
c)
Apply pressure only in direct line with the bit
and do not apply excessive pressure.
Bits
can bend causing breakage or loss of control,
resulting in personal injury.
Safety warnings for battery
a)
Do not open the battery.
Danger of
shortcircuiting.
b)
Protect the battery against heat, e. g.,
against continuous intense sunlight, fire,
water, and moisture.
Danger of explosion.
c)
In case of damage and improper use of the
battery, vapours may be emitted. Ventilate
the area and seek medical help in case
of complaints.
The vapours can irritate the
respiratory system.
d)
Use the battery only in conjunction with your
Ferm Industrial product.
This measure alone
protects the battery against dangerous overload.
e)
The battery can be damaged by pointed
objects such as nails or screwdrivers or by
force applied externally.
An internal short
circuit can occur and the battery can burn,
smoke, explode or overheat.
Safety warnings for charger
Intended use
Charge only CDA1132P and CDA1133P type
rechargeable Battery packs with the charger.
Only use the following batteries of the Ferm
Industrial FI20V battery platform. Using any other
batteries could cause serious injury or damage
the tool.
CDA1132P 20V, 2Ah Lithium-Ion
CDA1133P 20V, 4Ah Lithium-Ion
The following charger of the can be used to
charge these batteries.
CDA1131P Quick charger
The batteries of the Ferm Industrial FI20V battery
platform are interchangeable with all the Ferm
Industrial FI20V battery platform tools.
Residual risks
Even when the power tool is used as
prescribed it is not possible to eliminate all
residual risk factors. The following hazards
may arise in connection with the power tool’s
construction and design:
a) Health defects resulting from vibration
emission if the power tool is being used
over longer period of time or not adequately
managed and properly maintained.
b) Injuries and damage to property to due to
broken accessories that are suddenly dashed.
Warning!
This power tool produces an
electromagnetic field during operation.
This field may under some circumstances
interfere with active or passive medical
implants. To reduce the risk of serious or
fatal injury, we recommend persons with
medical implants to consult their physician
and the medical implant manufacturer
before operating this power tool.
Power cord replacement
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
2. MACHINE INFORMATION
Intended use
The impact driver is intended for driving in and
loosening screws.
Technical specifications
Machine
CDM1142P
Voltage
20V
Tool holder
6.35 mm ¼” internal
hexagon
No load speed
0-2900/min
Impact rate
0-3300/min
Max torque
150 Nm
Machine screw diameter
M6–M14mm
Weight (without battery pack)
1.18 kg
Sound pressure level
L
pA
80.0 dB(A), K=3dB(A)
Sound power level
L
wA
91.0 dB(A), K=3dB(A)
Vibration
1.740 m/s
2
K=1.5 m/s
2
Summary of Contents for CDM1142P
Page 2: ...2 Fig A 12 7 8 2 10 1 9 3 4 11...
Page 3: ...3 Fig C Fig B 3 2 2 5 6 1 2...
Page 87: ...87 BG II 40 T2 0A a a a Ferm Industrial CDA1132P CDA1133P...
Page 90: ...90 BG LED 6 C 2 LED 6 2 60 1 4 6 35 mm 10 8 A 10 10 A 11 11 11 10 9 A...
Page 91: ...91 BG 12 A 10 12 4 2012 19...
Page 92: ...92 EL 20V CDM1142P Ferm Ferm 1 m II 40 C Li ion T2 0A...
Page 95: ...95 EL B B 1 2 B C 4 3 C 2 2 5 C LED 6 LED 6 C 2 LED 6 LED LED 2 60 6 35 mm 1 4...
Page 97: ...97 AR 20 CDM1142P Ferm Ferm 1 04...
Page 100: ...100 AR 2 5 2 6 LED 6 LED 6 LED LED LED 60 6 53 10 8 10 10 11 11 11 10 9 12 10 12 4...
Page 101: ...101 AR 2012 19 EU...
Page 102: ...102...
Page 103: ...103...
Page 105: ...105 Exploded view...
Page 106: ...106...
Page 108: ...WWW FERM COM 2020 FERM 2001 02...